3-284
S ASCII code
HEX
conversion
S ASCII code
HEX
conversion
D22 high byte H 39 “9” D26 high byte H 31 “1”
D23 low byte H 41 “A” D27 low byte H 32 “2”
D23 high byte H 42 “B” D27 high byte H 33 “3”
4. When n = 4, the bit structure will be as:
0 1 0 0 1 0 1 1 10 0 0 0000
0 0 0 0 1 1 0 1 0 1 0 11 0 0 0
1 0 0 1 1 1 1 0 1 1 11 0 1 1 1
C D E F
D10
D20
D21
44H D
46H F
43H C
45H E
5. When n = 1 ~ 16:
D
n
D13 D12 D11 D10
1
The
undesignated
parts in the
registers in use
are all 0.
***C H
2
**CD H
3 *CDE H
4
CDEF H
5
***C H
DEF8 H
6
**CD H
EF89 H
7
*CDE H
F89A H
8
CDEF H
89AB H
9
***C H
DEF8 H
9AB4 H
10 **CD H EF89 H AB45 H
11
*CDE H
F89A H
B456 H
12
CDEF H
89AB H
4567 H
13 ***C H DEF8 H 9AB4 H 5670 H
14
**CD H
EF89 H
AB45 H
6701 H
15 *CDE H F89A H B456 H 7012 H
16 CDEF H 89AB H 4567 H 0123 H