Chapter 9 SpecificationsMS300
193
Heavy load (Pr.00-16=1)
Space Vector Modulation Mode (Pr.11-41 = 2)
Figure 9-9
The rated output current (%) of SVPWM in heavy load for different carrier frequencies:
Carrier Freq.
(kHz)
Ambient Temp.
(Ta), 100% Load
2
3
4
5
6
7
8
9
10
11
12
13
14
15
50°C
100
100
100
88
80
72
65
59
53
48
44
40
36
33
40°C
100
100
100
100
95
86
78
71
65
59
54
50
46
42
35°C
100
100
100
100
100
93
84.5
77
71
64.5
59
55
51
46.5
Table 9-17
Two-phase Modulation Mode (Pr.11-41 = 0)
Figure 9-7
The rated output current (%) of DPWM in heavy load for different carrier frequencies:
Carrier Freq.
(kHz)
Ambient Temp.
(Ta), 100% Load
2
3
4
5
6
7
8
9
10
11
12
13
14
15
50°C
100
100
100
100
100
93
86
80
74
69
65
61
57
53
40°C
100
100
100
100
100
100
100
95
89
83
78
73
69
65
35°C
100
100
100
100
100
100
100
100
96.5
90
84.5
79
75
71
Table 9-18

Table of Contents