Page #35 background imageLoading...
Page #35 background image
TP70P Quick Start
2-14
Related device
Item
Object
description
Button/Objec
t type
Communication
method
Device
address
Other settings
9 Error message
Message
Diaplay
COM3, station
address 1
$2100
Total States
: 21
Display Sequence
:
From Min
to Max
Current State
(
Device
Value
>=
Range Value
): Please
refer to the table below.
0 No error occurs.
1 Overcurrent
2 Overvoltage
3 Overheating
4
The drive is
overloaded.
5
The motor is
overloaded.
6 External fault
7 CPU failure
8
CPU failure or analog
circuit failure
9
Hardware protection
failure
10
There is overcurrent
during the
acceleration.
11
There is overcurrent
during the
deceleration.
12
There is overcurrent
during the steady
operation.
13 Ground fault
14 Low voltage
15 Reserved
16 CPU failure
17 Base block
18 Overload
19
Automatic
acceleration/decelerati
on failure
20
The software
protection is enabled.