Chapter 11 Description of Parameter Settings|C200 Series
11-65
AFM 1
1032
NOTE
2 =8 2 =4 2 =2 2 =1
32 1 0
AFM 2
3 2 1 0
2 2 2 2
Weights
Bit
0=ON
1=OFF
For Example:
If the value of Pr.02-30 displays 0002h(Hex), it means AFM1and AFM2 are used by PLC.
Bit
AFM 1
1000
2 2 2 2
3 2 1 0
Display value
2=1x2 +0x2
=bit 1x2 +bit 0x2
10
10
AFM 2
Weights
0=Not used by PLC
1=Used by PLC
AFM2 0-20mA Output Selection
Factory Setting: 0
Settings 0: 0-20mA output
1: 4-20mA output
AFM1 DC Output Setting Level
AFM2 DC Output Setting Level
Factory Setting: 0.00
Settings 0.00~100.00%
~
Reserve
Keypad potentiometer Selection
Factory Setting:0
Settings 0: No Function
1: Frequency Command
Keypad potentiometer input Bias
Factory Setting:0.0
Settings -100.0~100.0%
Keypad potentiometer positive/negative Bias Mode
出廠設定值:0
Settings
0: No bias
1: Lower than or equal to bias
2: Greater than or equal to bias
3: The absolute value of the bias voltage while serving as the center