Chapter 10 Summary of Parameter Settings|C200 Series
10-23
07 Special Parameters
Parameter Explanation Settings
Factory
Setting
07-00 Software Brake Level
230V: 350.0~450.0Vdc
460V: 700.0~900.0Vdc
380.0
760.0
07-01 DC Brake Current Level 0~100% 0
07-02 DC Brake Time at Start-up 0.0~60.0 sec. 0.0
07-03 DC Brake Time at Stop 0.0~60.0 sec. 0.0
07-04
Startup Frequency for DC
Brake
0.00~600.00Hz 0.00
07-05 Reserved
07-06
Restart after Momentary
Power Loss
0: Stop operation
1: Speed search for last frequency command
2: Speed search for minimum output frequency
0
07-07
Maximum Power Loss
Duration
0.1~20.0 sec. 2.0
07-08 Base Block Time 0.1~5.0 sec. 0.5
07-09
Current Limit for Speed
Search
20~200% 50
07-10
Treatment to Reboots After
Fault
0: Stop operation
1: Speed search starts with current speed
2: Speed search starts with minimum output frequency
0
07-11 Auto Restart After Fault 0~10 0
07-12
Speed Search during
Start-up
0: Disable
1: Speed search for maximum output frequency
2: Speed search for start-up motor frequency
3: Speed search for minimum output frequency
0
07-13
Decel. Time to Momentary
Power Loss
0: Disable
1: 1st decel. time
2: 2nd decel. time
3: 3rd decel. time
4: 4th decel. time
5: current decel. time
6: Auto decel. time
0
07-14 DEB Return Time 0.0~25.0sec 0.0
07-15 Dwell Time at Accel. 0.00 ~ 600.00sec 0.00
07-16 Dwell Frequency at Accel. 0.00 ~ 600.00Hz 0.00
07-17 Dwell Time at Decel. 0.00 ~ 600.00sec 0.00
07-18 Dwell Frequency at Decel. 0.00 ~ 600.00Hz 0.00
07-19 Fan Cooling Control
0: Fan always ON
1: 1 minute after the AC motor drive stops, fan will be
OFF
2: When the AC motor drive runs, the fan is ON. When
the AC motor drive stops, the fan is OFF
3: Fan turns ON when preliminary heat sink
temperature (around 60
o
C) is attained.
4: Fan always OFF
0
07-20
Emergency Stop (EF) &
Force to Stop Selection
0: Coast stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: System Deceleration
6: Automatic Deceleration
0
07-21
Auto Energy-saving
Operation
0: Disable
1: Enable
0
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Related product manuals