Chapter 1 IntroductionC2000 Series
1-1
Chapter 1 Introduction
1-1 Receiving and Inspection
After receiving the AC motor drive, please check for the following:
1. Please inspect the unit after unpacking to assure it was not damaged during shipment. Make sure that
the part number printed on the package corresponds with the part number indicated on the
nameplate.
2. Make sure that the voltage for the wiring lie within the range as indicated on the nameplate. Please
install the AC motor drive according to this manual.
3. Before applying the power, please make sure that all the devices, including power, motor, control
board and digital keypad, are connected correctly.
4. When wiring the AC motor drive, please make sure that the wiring of input terminals “R/L1, S/L2, T/L3”
and output terminals”U/T1, V/T2, W/T3” are correct to prevent drive damage.
5. When power is applied, select the language and set parameter groups via the digital keypad
(KPC-CC01). When executes trial run, please begin with a low speed and then gradually increases
the speed untill the desired speed is reached.
1-2 Nameplate Information
MODEL:VFD007C43A
INPUT:
Normal Duty: 3PH 380-480V 50/60Hz 4.3A
Heavy Duty: 3PH 380-480V 50/60Hz 4.1A
OUTPUT:
Ver si on :
FREQU ENCY RA NGE:
Normal Duty: 3PH 0-480V 3A 2.4KVA 1HP
Heavy Duty: 3PH 0-480V 2.9A 2.3KVA 1HP
Normal Duty: 0 -59 9Hz
Heavy Duty: 0-300Hz
VX.XX
007C43A7T14300002
DE LTA EL ECTRONICS. INC .
MA DE IN XXXXXX X
AC Drive Model
Input Voltage/Current
Output Voltage/Current
Frequency Range
Firmware Version
Certif cations
Serial Number
Enclosure type (IPXX)
i
Question and Answer IconNeed help?

Do you have a question about the Delta VFD015C43A and is the answer not in the manual?

Delta VFD015C43A Specifications

General IconGeneral
BrandDelta
ModelVFD015C43A
CategoryMedia Converter
LanguageEnglish

Summary

AC Drive Receiving and Inspection

AC Drive Nameplate Information

AC Drive Model Name Decoding

AC Drive Serial Number Structure

RFI Jumper Installation and Usage

RFI Jumper: Floating Ground Systems

Handling floating ground systems: RFI jumper removal, EMC considerations, and safety precautions.

RFI Jumper: Asymmetric Ground Systems

Precautions for asymmetric ground systems: when to remove the RFI jumper to prevent drive damage.

AC Drive Physical Dimensions

Frame A Drive Dimensions

Physical dimensions and mounting hole details for AC motor drive Frame A.

Related product manuals