EasyManua.ls Logo

Delta VFD015CB21A-21 - Page 325

Delta VFD015CB21A-21
363 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 14 PLC Function |C200 Series
14-40
Mnemonic Codes STEPS
API
16-bit 32-bit
P
Command
Function
16bit 32bit
219 ANDl DANDl -
Contact Logical Operation
AND#
5 9
220 AND^ DAND^ -
Contact Logical Operation
AND#
5 9
221 OR& DOR& -
Contact Logical Operation
OR
5 9
222 OR| DOR| -
Contact Logical Operation
OR
5 9
223 OR^ DOR^ -
Contact Logical Operation
OR
5 9
224
LD DLD
- Load Compare LD 5 9
225
LD DLD
-
Load Compare LD
5 9
226
LD DLD
-
Load Compare LD
5 9
228
LD<> DLD<>
-
Load Compare LD
5 9
229
LD<= DLD<=
-
Load Compare LD
5 9
230
LD>= DLD>=
-
Load Compare LD
5 9
232
AND DAND
-
AND Compare
5 9
233
AND DAND
-
AND Compare
5 9
234
AND DAND
-
AND Compare
5 9
236
AND<>
DAND
-
AND Compare
5 9
237
AND<=
DAND
-
AND Compare
5 9
238
AND>=
DAND
-
AND Compare
5 9
240
OR DOR
-
OR compare
5 9
241
OR DOR
-
OR compare
5 9
242
OR DOR
-
OR compare
5 9
244
OR<> DOR<>
-
OR compare
5 9
245
OR<= DOR<=
-
OR compare
5 9
Contact Type
Comparison
246
OR>= DOR>=
-
OR compare
5 9
139 RPR 9 Read the parameters 5
140 WPR 9 Write the parameters 5
141 FPID 9 Drive PID control 9
142
FREQ
9 Control the drive frequency
7 –
261
CANRX
9 Read CANopen Slave data
9 -
263
TORQ
9 Set target torque
5 -
264
CANTX
9 Write CANopen Slave data
9 -
Special
command for
AC motor
drive
265
CANFLS
9
Update the mapping
special D of CANopen
3 -