Chapter 14 PLC Function |C200 Series
14-51
API
24 D
INC
P
D
Increment: BIN plus 1
Bit Devices Word Devices
X Y M K H KnX KnY KnM T C D
D
Operands: none
16-bit command (3 STEPS)
INC
INCP
32-bit command (5 STEPS)
Flag signal: none
Explanation
1. D: Destination device
2. If the instruction is not a pulse execution one, the content in the
designated device D will plus “1” in every scan period whenever the
instruction is executed.
3. This instruction adopts pulse execution instructions (INCP).
4. In 16-bit operation, 32,767 pluses 1 and obtains -32,768. In 32-bit
operation, 2,147,483,647 pluses 1 and obtains -2,147,483,648.
Example
When X0 goes from Off to On, the content in D0 pluses 1 automatically.
X0
INCP D0