Chapter 14 PLC Function |C200 Series
14-60
API
232~
238
D
AND
S1 S2
AND Compare
Bit Devices Word Devices
X Y M K H KnX KnY KnM T C D
S
1
S
2
Operands: : =, >, <, <>,,
Please refer to the specifications of each model for the
range of operands.
16-bit command (5 STEPS)
AND
ZRSTP
32-bit command (9 STEPS)
DAND
Flag signal: none
Explanation
1. S
1
: Data source device 1 S
2
: Data source device 2
2. This instruction compares the content in S
1
and S
2
. Take API232 (AND=) for
example, if the result is “=”, the continuity of the instruction is enabled. If the result
is “, the continuity of the instruction is disabled.
3. AND ( : =, >, <, <>, , ) is a comparison instruction is used on series
contacts
API No.
16 –bit
instruction
32 –bit
instruction
Continuity
condition
No-continuity
condition
232
AND DAND S
1
S
2
S
1
S
2
233
AND DAND S
1
S
2
S
1
S
2
234
AND DAND S
1
S
2
S
1
S
2
236
AND<> DAND<>
S
1
S
2
S
1
S
2
237
AND<= DAND<=
S
1
S
2
S
1
S
2
238
AND>= DAND>=
S
1
S
2
S
1
S
2
Example
1. When X0 = On and the content in C10 = K200, Y10 = On.
2. When X1 = Off and the content in D0 K-10, Y11= On will be retained.
3. When X2 = On and the content in 32-bit register D0 (D11) < 678,493 or M3 =
On, M50 = On.
AND=
K200 C10
DAND>
K678493 D10
M3
Y10
AND<>
K-10 D0
SET Y11
M50
X2
X1
X0