Chapter 11 Summary of Parameter SettingsC2000 Plus
11-18
Pr. Parameter Name Setting Range Default
33: Zero speed (actual output frequency)
34: Zero speed including stop (actual output
frequency)
35: Error output selection 1 (Pr.06-23)
36: Error output selection 2 (Pr.06-24)
37: Error output selection 3 (Pr.06-25)
38: Error output selection 4 (Pr.06-26)
39: Position reached (Pr.11-65, Pr.11-66)
40: Speed reached (including stop)
42: Crane function
43: Motor actual speed detection
44: Low current output (use with Pr.06-71–06-73)
45: UVW output electromagnetic valve switch
46: Master dEb output
47: Closed brake output
49: Homing action completed
50: Output control for CANopen
51: Analog output control for RS-485 interface
(InnerCOM / Modbus)
52: Output control for communication cards
65: Output control for both CANopen and RS485
66: SO output logic A
67: Analog input level reached
68: SO output logic B
70: FAN warning output
75: Forward running status
76: Reverse running status
02-18 Multi-Function Output Direction 0000h–FFFFh (0: N.O.; 1: N.C.) 0000h
02-19
Terminal Counting Value Reached
(Returns to 0)
0–65500 0
02-20
Preliminary Counting Value Reached
(Does Not Return to 0)
0–65500 0
02-21 Digital Output Gain (DFM) 1–166 1
02-22 Desired Frequency Reached 1 0.00–599.00 Hz
60.00 /
50.00
02-23
The Width of the Desired Frequency
Reached 1
0.00–599.00 Hz 2.00
02-24 Desired Frequency Reached 2 0.00–599.00 Hz
60.00 /
50.00
02-25
The Width of the Desired Frequency
Reached 2
0.00–599.00 Hz 2.00
02-32 Brake Delay Time 0.000–65.000 sec. 0.000