Chapter 11 Summary of Parameter SettingsC2000 Plus
11-58
Pr. Parameter Name Setting Range Default
11-62
Encoder at Load Side ppr Number
(High Byte)
0–65535 0
11-63
Encoder at Load Side ppr Number
(Low Byte)
0–65535 2400
11-64
Single-Point Positioning Rising
Speed
0.10–depending on the maximum setting value
calculated by setting value of Pr.11-43 and Pr.11-45
10.00
11-65
Single-Point Positioning Position
(High Byte)
0–ppr number at load side 0
11-66
Single-Point Positioning Position
(Low Byte)
0–ppr number at load side 0
11-68
Homing Method
0000h–0128h 0008h
11-69
Homing Control Time Out
0.0–6000.0 sec. 60.0
11-70
Homing Control 1
st
Step Speed
0.00–599.00 Hz 8.00
11-71
Homing Control 2
nd
Step Speed
0.00–599.00 Hz 2.00
11-72
Homing Control Acceleration /
Deceleration Time
(0–Homing Control 1
st
Step
Speed)
0.00–600.00 sec. 10.00
11-73
Homing Control Offset
(Revolution)
-30000–30000 revolutions 0
11-74
Homing Control Offset (Pulse)
Refer to Pr.10-01 setting 0
11-75
Position Record (Revolution)
-30000–30000 revolutions 0
11-76
Position Record (Pulse)
Refer to Pr.10-01 setting 0
11-78
HALT Revived Selection
0: Stopped
1: Continue according to the previous position
command
0