Chapter 10 Auto-tuning Process | VFD-ED
10-5
Press
Setting values:
1: External terminals (work with controller)
2: RS-485 serial communication or digital keypad (KPC-CC01) (does not work with
controller)
Pr.02-01Pr.02-08 Multi-function Input Settings
Press
Press
The default value of Pr.02-08 is 40 (Enable Drive). If you do not need this function (does
not work with controller), set the setting value to 0.
Setting value:
0: No function
1: Multi-step speed command 1
2: Multi-step speed command 2
3: Multi-step speed command 3
4: Multi-step speed command 4
5: Reset
6: JOG command
7: Acceleration/deceleration speed inhibit
8: First, second acceleration/deceleration time
9: Third, fourth acceleration/deceleration time
10: EF input (Pr.07-28)
11: Reserved
12: Stop output
1314: Reserved
15: AUI1 operation speed command
16: Reserved
17: AUI2 operation speed command
18: Emergency Stop (Pr.07-28)
1923: Reserved
24: FWD JOG Command
25: REV JOG Command