Chapter 11 Summary of Parameter SettingsME300 
 
11-20 
 
Pr.  Explanation  Settings  Default 
  05-21 
Stator inductance (Lx)   
for induction motor 2 
0.0–6553.5 mH 
#.# 
  05-22 
Multi-motors (induction) 
selection 
1: Motor 1 
2: Motor 2 
1 
 
05-23 
Frequency for   
Y-connection /Δ-connection 
switch for an induction 
motor 
0.00–599.00 Hz
  60.00 
  05-24 
Y-connection /Δ-connection 
switch for an induction 
motor 
0: Disable 
1: Enable
 
0 
 
05-25 
Delay time for   
Y-connection /Δ-connection 
switch for an induction 
motor 
0.000–60.000 sec.
  0.200 
  05-28 
Accumulated Watt-hour 
for a motor (W-hour) 
Read only  0.0 
  05-29 
Accumulated Watt-hour 
for a motor in low word 
(kW-hour) 
Read only  0.0 
  05-30 
Accumulated Watt-hour 
for a motor in high word 
(MW-hour) 
Read only  0.0 
  05-31 
Accumulated motor 
operation time (minutes) 
0–1439 min.  0 
  05-32 
Accumulated motor 
operation time (days) 
0–65535 days  0 
  05-33 
Induction motor (IM) or 
permanent magnet 
synchronous motor 
selection 
0: Induction motor 
1: SPM 
2: IPM 
0 
  05-34 
Full-load current for a 
permanent magnet 
synchronous motor 
0–120% of the drive’s rated current  #.# 
  05-35 
Rated power for a 
permanent magnet 
synchronous motor 
0.00–655.35 kW  #.## 
  05-36 
Rated speed for a 
permanent magnet 
synchronous motor 
0–65535 rpm  2000