DRA-38S5RD
ma
METHOD
OF
ADJUSTMENTS
3]
9
T.P
6
Leh
ey
DC
VOLTMETER
vrsos
CT
game
O
{@
vrsos
O
eee
ee
2
TP
i
©
Reh
f
IDLING
CURRENT
(1)
Set
controls
as
follows.
POWER
Switch
-
off
(ML)
VOLUME
Control
0
(min.)
SPEAKERS
off
(ME)
Temperature
15°C
~
30°C
(59°F
~
86°F)
VR305
and
VR306
of
the
1U-2817-1
(Main
Unit)
>
MIN.
(C*)
(2)
Connect
DC
Voltmeter
to
the
T.P
Lch
and
T.P
Rch
of
the
1U-2817-1.
(3)
Turn
the
Power
Switch
on
and
rotate
VR305
clockwise
so
that
the
DC
Voltmeter
reads
2.5
mV
+0.2
mV
DC
at
the
T.P
Lch.
Follow
the
same
procedure
to
VR306
for
T.P
Reh.
(4)
Warm
up
for
three
minutes,
then
readjust
VR305
and
VR306
so
that
the
DC
Voltmeter
reads
2.5
mV
+0.5
mV
DC.
(5)
Warm
up
for
10
minutes,
then
readjust
VR
305
and
VR306
so
that
the
DC
Voltmeter
reads
2.5
mV
+0.5
mV
DC.
"1