ADJUSTMENT
Idling
Current
Required
measurement
equipment
and
tool:
*
DC
Voltmeter
¢
Small
screwdriver,
1mm
width
(—)
Preparation
(1)
Avoid
direct
blow
from
an
air
conditioner
or
an
electric
fan,
and
adjust
the
unit
at
normal
room
tempereture
15
°C
~
30
°C
(59
°F
~
86
°F).
(2)
Presetting
@
POWER
(Power
sourse
switch)
OFF
@
SPEAKER
(Speaker
terminal)
~
No
load
(Do
not
connect
speaker,
dummy
resistor,
etc.)
Note:
The
following
adjustment
should
be
performed
from
the
foil
side
of
the
P.W.B.
Adjustment
(1)
Remove
top
cover
and
set
SR201,
SR101,
SR301
on
Amp.
Unit
at
the
center
position.
(2)
Connect
DC
Voltmeter
to
test
points,
Lch:
J173(-),
J166(+),
Reh:
J163(-),
J154(+),
Och:
J147(-),
J129(+).
(3)
Connect
power
cord
to
AC
Line,
and
turn
power
switch
"ON".
(4)
Within
2
minutes
after
the
power
on,
turn
SR201
to
adjust
the
TEST
POINT
voltage
to
5.5
mV
+1.0
mV
DC.
(5)
Adjust
the
Variable
Resistors
of
other
channels
in
the
same
way.
AMP
P.W.B.
‘to
J154
(+)
J173
(-)
M1
‘TH.
J129
(+)
[1]
ey
®
SR101
SR201
SR301
Power
SW