EasyManua.ls Logo

Deus CT1 24 - Wiring and Connections; Control Unit Connections

Deus CT1 24
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P.10
1
2
6
15 - 16
16
17
3.2 - Control unit connec!ons
Terminal
Descrip!on
ANTENNA: Antenna braid input, use RG58-50 Ohm cable.
COMMON COMMANDS: For the inputs: STOP - OPEN - CLOSE - STEP BY STEP - SECURITY - PHOTO.
6 - 7
STOP: NC input Determines the gate’s halt.
Safety devices such as an emergency stop bu!on can be connected to it. When the command is
released, the automa"c closing is never performed, movement is only restored with a new
command.
OPENING: NO input Determines the opening of the gate.
CLOSING: NO input Determines the closure of the gate.
13 - 14
NC = Normally Closed Contact - NO = Normally Opened Contact
Brown
+ Encoder
- Encoder
Motor
- Before proceeding with the wiring and connec"ons, carefully read what is wri!en in the
REQUIREMENTS AND WARNINGS FOR SAFETY and INSTRUCTIONS AND WARNINGS FOR
INSTALLATION.
- All wiring and connec"on opera"ons must be carried out with the power supply disconnected.
If the device is not visible, a warning plate must be affixed: “ATTENTION: UNDER MAINTENANCE”.
ANTENNA: Antenna input
Func!on
Encoder A - B
OPENING SAFETY: NC input for opening safety devices.
During the gate opening cycle, the interven"on of the safety determines a short inversion.
FLASHING: 24 Vdc 5 W max output, for connec"ng the flashing light.
STEP BY STEP: NO input Determines the gate movement according to the following cycles:
SEMIAUTOMATIC: Open, Pause, Close, Pause.
CONDOMINIUM: Open (with automa"c closing ac"ve).
SEMIAUTOMATIC: Open, Stop, Close, Stop.
SEMIAUTOMATIC: Opens, Closes.
SEMIAUTOMATIC: Man’s switch.
6 - 8
6 - 9
6 - 10
6 - 11
3.1 - Wiring and connec!ons
RELAY CONTACT: Contact output Mul"func"on relay, with OPTION [8]:
Opened gate light - Courtesy light - Radio contact.
+
-
30 Vdc OUTPUT: To power auxiliary devices, max 200mA.
Cable colorTerminals
6 - 12
PHOTOCELL: NC input for photocells or safety devices.
It does not intervene during the gate opening cycle.
During the closing cycle of the gate, it reverses the movement un"l it is completely opened.
Green yellow
White
Blue / Red
Black / Red
Transformer - / Transformer +
6 - 8/9
PEDESTRIAN: With the simultaneous ac"va"on of the two inputs 8 and 9, the gate opens in
pedestrian mode following the se%ngs in the SETTINGS menu [6].
2 - 3
1
4
5 - 6
7 - 8