1.1 Technical Specifications
Operation voltage 220-240V~, 50Hz
Power consumption Max 5W
Relay:
Resistive load Max 16A / 3680W @ 230V
Inductive load cos φ= 0.3 max 1A
Sensing units NTC 15 kOhm at 25°C
Sensing values:
0°C 42 kOhm
25°C 15 kOhm
50°C 6 kOhm
Hysteresis ± 0.2°C
Ambient temperature 0 to +30°C
Frost protection temperature 5°C -
Temperature range
(
) 5-45°C
Cable specification max
1x4mm
2
or 2x2,5mm
2
Ball pressure temperature 75°C
Pollution degree Degree 2 (domestic use)
Type 1C
Storage temperature -20 to +65°C
DEVIreg™ 130
4 Installation Guide