3. Choose sensor combination
When installing the Devireg™ 535 you need to choose
the type of heating and thus which sensors should be
used. You have three options:
Comfort heating: Constant temperature on the floor in
bathrooms and other rooms where a comfortable warm
surface is required.
Install the Floor sensor and choose only the Floor sensor.
Total heating: Control of room temperature in living
rooms etc. Install the Floor sensor and choose both
Floor sensor and Room sensor.
No floor sensor: A floor sensor is not present, and
cannot be installed. Choose Room sensor. (Not
recommended).
Be aware that without a floor sensor, the temperature
control can be less accurate, and overheating of the
floor is of higher risk.
DEVI recommends that a floor sensor is always
installed.
When the thermostat is used to control a floor heating
element according to EN/IEC 60335-1 and
EN/IEC 60335-2-96, always use the floor sensor
and never set the temperature limit above 35°C.