The unit is not operating.
✓ Check the power connection in secure.
➢ Insert the power cord securely into the wall outlet.
✓ Check if the water level indicator light is
illuminated.
➢ Empty the water tank and reinstall correctly.
✓ Check the room temperature.
➢ The operating temperature range is 5-35℃.
There is little formation of
condensate.
✓ Check the air filter for dirt.
➢ Clean the air filter as necessary.
✓ Check if the air duct is blocked.
✓ Check if the room temperature is below 20℃.
➢ This is normal. Low humidity in low temperature
environment.
✓ Set humidity level is higher than current
humidity value.
➢ Set the humidity level below current humidity
value.
✓ Overflow while moving the unit.
➢ Empty the water tank before transporting the unit.
✓ Check if the drain hose is kinked or bent.
➢ Straighten the hose to avoid a trap existing.
✓ Check if the unit is securely positioned.
➢ Place the unit on horizontal, firm and flat ground.
✓ Check for any loose or vibrating parts.
➢ Secure and tighten the parts.
✓ Noise sounds like water flowing.
➢ Noise comes from flowing refrigerant. This is
normal.
✓ Humidity sensor dampened or failure.
➢ Clean or replace the humidity sensor.
✓ Display when Room temperature is below 5°C
(41°F).
➢ Normal. The compressor stops, and the fan keeps
running.
✓ Display when Room temperature is above38℃
(100°F).
➢ Normal. The compressor stops, and the fan keeps
running.
✓ Display when Room relative humidity is below
20%RH.
➢ Normal. The compressor stops, and the fan keeps
running.
✓ Display when room relative humidity is above
90%RH.
➢ Normal. The compressor and the fan keep
running.