EasyManua.ls Logo

DEVOLA DV20LWF - Settings

DEVOLA DV20LWF
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
5. OPERATION
5.1 DIGITAL DISPLAY
5.2 CONTROL PANEL
5.3 SETTINGS
Power
In the standby state, press the power button to turn on, the operation indicator lights up and the
default fan speed is high, the LED shows ambient humidity. In the power-on state, press the
power button to turn off, the running indicator light goes off and the compressor stops
immediately, and then the fan will shut down after 30 seconds.
Mode
There are three modes: Auto mode, continuous drying mode, and a sleeping cycle mode. Press
once to switch the mode from one to another, the corresponding indicator lights up.
Auto mode: when the environmental humidity set is +3%, the fan starts working and
compressor starts working after 3 seconds. When environmental humidity ≤ set humidity -3%,
the compressor stops working and fan stops working after 30 seconds.
Both fan speed and humidity can be adjusted under auto mode.
Continuous drying mode: The machine continues to run, but the humidity cannot be
adjusted.

Related product manuals