EasyManua.ls Logo

DeWalt D55140

DeWalt D55140
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
16 Loose electrical connections Contact a DEWALT factory service center or a DEWALT
authorized service center.
Possible defective motorl ContaCt a DEWALT factoiy Service Center or a DEWALT
authorized service center.
18 Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
i9 Tank Pressuie exceeds PiesSuie switch cut,in pressuie Motor wi!l start automatically when tank pressure dropS
: below cut,in pressure of pressure switch.
17

Related product manuals