3
English
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Heater Specifications
CSA certied for use with only No. 1-K kerosene fuel. Factory Tested:
Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
MODEL NO.: .........................................................DXH90CFAK, DXH90CFAKM
BTU/hr: ...................................................................HIGH (MAX) 90,000 BTU/hr
(26.3 kW)
BTU/hr: ....................................................................LOW (ECO) 75,000 BTU/hr
(22 kW)
CONSUMPTION RATE: ......................................................... MAX 0.67 GAL/hr
(2.5 L/hr)
CONSUMPTION RATE: ......................................................... ECO 0.56 GAL/hr
(2.1 L/hr)
TANK CAPACITY: ...........................................................................4 GALLONS
(15.14 L)
FUEL RUN TIME: ......................................................................ECO: 6.3 hours
MAX: 5.25 hours
ELECTRICAL INPUT: .......................................................... 115 V, 60 HZ, 1.8 A
ASSEMBLED DIMENSIONS: ........................................... 13.25” X 25” X 22.25”
(33.6 cm X 63.5 cm X 56.5 cm)
DRY WEIGHT: ........................................................................30 lbs. (13.61 kg)
FULL WEIGHT: .........................................................................56 lbs. (25.4 kg)
APPROXIMATE HEATING AREA: ............................... 2250 SQ. FT (209 SQ. m)
THERMOSTAT RANGE: ...................................23°F to 99°F ( -5 °C to 37.2 °C )
WARNING: CERTIFIED FOR USE WITH DEWALT RECHARGEABLE BATTERY
PACKS REFER TO CHART BELOW A LIST OF APPROVED BATTERIES.
Approved Battery Packs
20V MAX* 12AH FLEXVOLT®
# of
Packs
Battery
Capacity
Run Time
Hr.**
Run Time
Min.**
# of
Packs
Battery
Capacity
Run Time
Hr.**
Run Time
Min.**
1 1.3Ah 0.65 39 1 6.0Ah 3 180
1 1.5Ah 0.75 45 1 9.0Ah 4.5 270
1 2.0Ah 1 60 1 12.0Ah 6 360
1 3.0Ah 1.5 90 2 6.0Ah 6 360
1 4.0Ah 2 120 2 9.0Ah 9 540
1 5.0Ah 2.5 150 2 12.0Ah 12 720
1 6.0Ah 3 180
1 9.0Ah 4.5 270
2 1.3Ah 1.3 78
2 1.5Ah 1.5 90
2 2.0Ah 2 120
2 3.0Ah 3 180
2 4.0Ah 4 240
2 5.0Ah 5 300
2 6.0Ah 6 360
2 9.0Ah 9 540
All run times are approximate. Actual run
times may vary. State of charge, battery
temperature and battery age will all affect
actual runtime
* Maximum initial battery voltage (measured
without a workload) is 20 volts. Nominal
voltage is 18.
**Calculation assuming 73°F (23°C) ambient
temp battery pack
Clearance To Combustibles
From Outlet From Sides From Top From Rear
8 ft (2.4m) 3ft (1 m) 3ft (1 m) 3ft (1 m)
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
- Service must be performed by a qualified service agency.
WARNING: If the information in this manual is not followed exactly, a
fire or explosion may result causing injury or loss of life.