EasyManua.ls Logo

DeWalt P3600 - Tool Malfunction Procedures; Delayed Load Discharge; Jammed or Broken Tool

DeWalt P3600
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P3600
EN
9
TOOL MALFUNCTION
1. In the event that a load fails to discharge after the trigger is pulled, the tool must be kept depressed
against the work surface for a minimum of 30 (thirty) seconds in case of a delayed load discharge. Then
carefully remove the entire load strip and store it in a can of water or other nonflammable liquid and
dispose in accordance with local jurisdiction and safety data sheet (SDS). Never attempt to force or pry a
load out of a tool chamber.
2. Never discard powder loads into a trash container or fire bin.
3. Do not attempt to unload or disassemble a jammed, stuck or broken tool as improper handling may
cause it to discharge and strike operator and/or bystander. A jammed tool must be pointed in a safe
direction at all times. Tag the tool and lock it up. Call your DEWALT representative for proper assistance.

Related product manuals