3
ENGLISH
READ ALL INSTRUCTIONS
1 . NEVER TOUCH MOVING PARTS. Never place your
hands, fingers or other body parts near the compressor’s
movingparts.
2 . NEVER OPERATE WITHOUT ALL GUARDS IN PLACE
Never operate this compressor without all guards or
safety features in place and in proper working order. If
maintenance or servicing requires the removal of a guard or
safety features, be sure to replace the guards or safety feature
before resuming operation of thecompressor.
3 . ALWAYS WEAR EYE PROTECTION. Always wear safety
goggles or equivalent eye protection. Compressed air
must never be aimed at anyone or any part of thebody.
4 . PROTECT YOURSELF AGAINST ELECTRIC SHOCK. Prevent
body contact with grounded surfaces such as pipes,
radiators, ranges and refrigeration enclosures. Never
operate the compressor in damp or wet locations. Never
leave the compressor exposed to adverse weatherconditions.
5 . DISCONNECT THE COMPRESSOR WHEN NOT IN USE.
Always disconnect the compressor from the power source and
remove the compressed air from the air tank before servicing,
inspecting, maintaining, cleaning, replacing or checking
anyparts.
6 . AVOID UNINTENTIONAL STARTING. Do not transport
the compressor over long distances, in a vehicle or in
potentially dangerous situations, for example, on a
ladder or scaffold while it is connected to its power
source or when the air tank is filled with compressed air.
Be sure the auto ON/ OFF switch is in the OFF position before
connecting the compressor to its powersource.
7 . STORE COMPRESSOR PROPERLY. When not in use, the
compressor should be stored in dry place. Keep out of
reach of children. Lock‑out the storagearea.
8 . KEEP WORK AREA CLEAN Cluttered areas invite injuries.
Clear all work areas of unnecessary tools, debris, furnitureetc.
9 . KEEP CHILDREN AWAY. Do not let visitors contact
compressor extension cord. All visitors should be kept safely
away from workarea.
10 . DRESS PROPERLY. Do not wear loose clothing or
jewellery. They can be caught in moving parts. Wear
protective hair covering to contain longhair.
11 . STAY ALERT. Watch what you are doing. Use common
sense. Do not operate compressor when you are tired.
Compressor should never be used by you if you are under
the influence of alcohol, drugs or medication that makes
youdrowsy.
12 . CHECK FOR DAMAGED PARTS AND AIR LEAKS. Before
further use of the compressor, carefully check the guard
and other parts for damage to make sure that it will
operate properly and perform its intended function.
Check for alignment of moving parts, binding of moving
parts, breakage of parts, mounting, air leak, and any
other conditions that may affect its operation. A guard
or other part that is damaged should be properly
repaired or replaced by an authorized service centre
unless otherwise indicated elsewhere in this Instruction
Manual. Have defective pressure switches replaced
by authorized service centre. Do not use compressor
if switch does not turn it on and off. Never attempt
to repair a leaking or damaged air tank. Replace tank
immediately at an authorized servicecentre.
13 . NEVER USE COMPRESSOR FOR APPLICATIONS OTHER
THAN THOSE SPECIFIED. Never use compressor for
applications other than those specified in the Instruction
Manual. Never use compressed air for breathing or
respiration. Never stand on thecompressor.
14 . HANDLE COMPRESSOR CORRECTLY. Operate the
compressor according to the instructions provided
herein. Never allow the compressor to be operated by
children, individuals unfamiliar with its operation or
unauthorisedpersonnel.
15 . KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY
IN PLACE. Keep all screws, bolts, and plates tightly
mounted. Check their conditionsperiodically.
16 . KEEP MOTOR AIR VENT CLEAN The motor air vent must
be kept clean so that air can freely flow at all times.
Check for dust build‑upfrequently.
17 . OPERATE COMPRESSOR AT THE RATED VOLTAGE.
Operate the compressor at voltages specified on their
nameplates. If using the compressor at a higher voltage
than the rated voltage, it will result in abnormally fast motor
revolution and may damage the unit and burn out themotor.
18 . NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR
OPERATING ABNORMALLY. If the compressor appears to
Batteries
Chargers/Charge Times (Minutes)
DCC1054
DC
Weight
Batteries Chargers/Charge Times (Minutes)
Cat # V
DC
Ah Weight (kg) DCB107 DCB113 DCB115 DCB118 DCB132 DCB119
DCB546 18/54 6.0/2.0 1.05 270 140 90 60 90 X
DCB547 18/54 9.0/3.0 1.25 420 220 140 85 140 X
DCB181 18 1.5 0.35 70 35 22 22 22 45
DCB182 18 4.0 0.61 185 100 60 60 60 120
DCB183/B 18 2.0 0.40 90 50 30 30 30 60
DCB184/B 18 5.0 0.62 240 120 75 75 75 150
DCB185 18 1.3 0.35 60 30 22 22 22 X
DCB187 18 3.0 0.48 140 70 45 45 45 90