64
DRIVE INTERNAL
Condition This error occurs when the control receives a message that the drive has experi-
enced an internal error.
Control
Action
When detected, the control turns o the motor and the heating relay. There is no
delay in the action once the criteria are met.
Exit The machine will not start and the Error Code will continue to be displayed until
the condition no longer exists and the prompt is followed to Reset the Error Code
and return the Machine to Idle Mode.
Customer
Action
Turn the power o to the washer. Wait one minute. Turn the power on to
the washer. If problem reappears, contact your Dexter representative.
DRIVE EXCEPTION
Condition This error occurs when the control receives a message that the drive has logged
an exception code.
Control
Action
When detected, the control turns o the motor and the heating relay. There is no
delay in the action once the criteria are met.
Exit The machine will not start and the Error Code will continue to be displayed until
the condition no longer exists and the prompt is followed to Reset the Error Code
and return the Machine to Idle Mode.
Customer
Action
AUTODRY OOR LOW
Condition This error occurs when the machine control sees output from the RMC sensor
(secondary) board that is out-of-range at 0V or lower.
Control
Action
When detected there is a delay of 5 minutes before the error is active. Once ac-
tive, the control will display the “AUTODRY OOR LOW” prompt and the current
drying stage will end. The next stage will begin and the error will continue to be
displayed alternating with the Cycle Progress screen during the remainder of the
stage.
Exit The Error Code will continue to be displayed until the cycle is stopped and the
control is returned to Idle mode.
Customer
Action
Part # 8533-112-001 7/21