56
Service Procedures
Pressure Testing
The dryer and its individual shuto valve must be disconnected from the gas supply piping system
during
any pressure testing of that system at test pressures in excess of ½ psig (14” water colum). The
dryer must be isolated from the gas supply piping system by closing its individual manual shuto
valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than ½ psig.
Clothes Door Removal
Step 1: Open door and remove inner hinge plate cover by removing the two Phillips screws.
Step 2: The clothes door may be removed from the hinge bracket by unscrewing and
removing the top 3/16 allen head pivot screw located at the door upper hinge point, you will also
need to use a ¼ allen wrench in the lower fastner.
Step 3: Next lean the door out of the top of the hinge bracket and lift the door from the
bottom hinge pin.
Front Panel Removal
Step 1: Remove the loading door from the panel (optional, the front panel may be removed without
taking o the door).
Step 2: Open upper service door, and remove lint door.
Step 3: Then remove the two left side phillips screws w/beveled washers and the two right side
phillips w/beveled washers screws. Next disconnect door switch wires from back of loading door
switch.
Prssure
testing port
incoming
Prssure
testing port
outgoing
3/16 Allen
1/4 Allen
Part # 8533-088-001 7/21