Trouble Shooting Fault Codes
F1 Shorted sensor or shorted sensor wire harness
F2 Open sensor or sensor wire harness disconnected
F3 Possible grounding problem. Try powering down and repowering and then push programming
button to start dryer. Try resetting with Palm Pilot (extra utilities fi le). If no success. Try
removing battery and reinstall battery.
F4 Micro Chip Problem. Replace controller.
F5 Microchip Electrical Problem. Remove power for 1 minute and then power on. Try removing
battery and reinstalling on control PCB/
TROUBLESHOOTING TIPS
Symptom Probable Cause Suggested Remedy
Tumbler does not turn Drive belts Check both drive belts.
Replace if failed.
Drive motor Check capacitor and motor.
Replace if failed
Door switch Check door switch contacts
and adjustment. Adjust or
replace door switch.
Electronic Control Is electronic control closing
motor relay to power drive
motor? Check for motor light
on electronic control. If no
light change control. If light is
on, check voltage and wiring
to motor.
3
Part # 8533-061-001 11/13