Command descriptions set autoconnect
ConnectPor LTS Command Reference
52
set autoconnect
Purpose
Used to establish an automatic connection (autoconnection) between the serial port and a remote
network destination, and to display current autoconnect settings.
Required permissions
For products with two or more users, to use this command, permissions must be set to one of the
following:
n For a user to display autoconnect settings for the line on which they are logged in: set
permissions s-autoconnect=r-self”
n For a user to display autoconnect settings for any line:
“set permissions s-autoconnect=read”
n For a user to display and set the autoconnect settings for the line on which they are logged in:
“set permissions s-autoconnect=rw-self”
n For a user to display autoconnect settings for any line, and set the autoconnect settings for the
line on which the user is logged in: set permissions s-autoconnect=w-self-r”
n For a user to display and set the autoconnect settings on any line: set permissions
s-autoconnect=rw See "set permissions" for details on setting user permissions for
commands.
Syntax
Configure autoconnect
set autoconnect
[port={
range
|xbee|internalmodem}]
[state={on|off}]
[trigger={always|data|dcd|dsr|string}]
[service={raw|rlogin|ssl|telnet|ssh}]
[description=
string
]
[ipaddress=
ip address
]
[ipport=
ip port
]
[connect on string=
string
]
[flush_string={on|off}]
[keepalive={on|off}]
[nodelay=on|off]
Display autoconnect settings
set autoconnect [port={
range
|xbee|internalmodem}]
Options
port={range|xbee|internalmodem}

Other manuals for Digi ConnectPort LTS8