PRODUCT GUIDE
Keypad | Basic & Advanced
10
POWER JUMPING A LOCK WITH A MANAGER KEY
Insert and leave a valid Manager Key into the key slot until the
lock operates.
Open the door.
See Lock Battery Replacement instructions.
CAUTION: Risk of explosion or leakage if battery is replaced by an incorrect type, mixed with a different battery type, or inserted
backwards. Replace all batteries of a set at the same time. Be sure to insert batteries with correct polarities. Remove exhausted batteries
from product promptly and dispose of used batteries according to the battery manufacturer’s instructions.
Remove the 2 screws from the cover plate with a #1 Phillips
screw driver.
Slide battery cover plate back and lift up to expose the batteries.
Manager and Programming Key Battery Replacement
Remove the batteries from the housing. Replace with four
premium alkaline AAA batteries.
Replace the cover plate and secure with the screws.