7
PROBLEMS SOLUTION
fault functional
anomaly
What to do
Led DL2 switches regularly on and off Overload
condition
Decrease reference voltage to
decrease the output power
At power on the led DL2 doesn't switch
momentary on and DL1 doesn't switches
at all
Device not
supplied
Verify mains supply and input
fuses; to locate fuses F1 see
instructions to open the device
At power on the led DL1 is off and led
DL2 switches momentary on, but
vibration doesn't start
There is not
start command
Place switch SW2 to on or send
a start command from input
cable
At power on the led DL1 switches on
and led DL2 switches momentary on,
but vibration doesn't start
Vibrator not
supplied
Check wiring from power
supply to vibrator; if the
problem is not there may be
there is a failure on drivers into
the power supply
If actions remarked on the table doesn't resolve the problem you may contact factory
digisystem srl (e-mail
info@digisystemsrl.it
) we will help you.
OPENING INSTRUCTIONS
As on the electronic card there are some capacitors with high voltage applied (presence of
residuary energy, danger of strike) you must wait at least 4 - 5 minutes after the device is
disconnected from the power supply, before opening the box.
Remove the four screws on the panel.