Nr. Functions Value
answer is either: 0 (No: always) or: 1 (Yes: only above).
160 Event Counter is momentarily suspended? - Event Counter 2 should be momentarily suspended? If not then it will be active.
The allowed answer is either: 0 (No: active) or: 1 (Yes: suspended).
No / Yes
COUNTER N. 3
161 Load-value Event-Counter n. 3: this is either the number of units, or the distance in metres, or the time in seconds, or the cost of the fare, or the cost of the extra charges
that should be counted for the tariff-block to be changed. The allowed value goes from 0 (min) to 65535 (max). The tariff-block to change to is to be programmed in Q.162.
0 – 65535
162 Block-Number (abs) at event n. 3: this is the block number (absolute) to be used when the event occured that has been programmed in Q.161. The allowed value goes
from 0 (min) to 62 (max). Also allowed is the value 255; In this case, instead of using a new block number, the former block number is used again.
0 - 62
163 Block-Offset (rel) at event n. 3: this is the block offset (relative) to be used when the event occured that has been programmed in Q.161. The relative block offset is the
number of blocks to add to the current block number in order to obtain the new block number. The allowed value goes from 0 (min) to 62 (max).
0 - 64
164 Load-value is Units? - Is the parameter programmed in Q.161 for event counter 3 the number of units? No / Yes
165 Load-value is Distance (in metres)? - Is the parameter programmed in Q.161 for event counter 3 the distance in metres? No / Yes
166 Load-value is Waiting-Time (in seconds)? - Is the parameter programmed in Q.161 for event counter 3 the waiting-time in seconds? No / Yes
167 Load-value is Cost of Fare? - Is the parameter programmed in Q.161 for event counter 3 the cost of the fare? No / Yes
168 Load-value is Cost of Extra-Charge? - Is the parameter programmed in Q.161 for event counter 3 the cost of the extra-charge? No / Yes
169 Reload every Metre? (if not: every Second) - Event Counter 3 must be reloaded every metre? If not then it will be reloaded every second.
The allowed answer is either: 0 (No: every second) or: 1 (Yes: every metre).
No / Yes
170 Act. Only Above cross-speed? (if not: Allw.) - Event Counter 3 should be activated only above the cross-speed? If not then it will allways be activated. The allowed
answer is either: 0 (No: allways) or: 1 (Yes: only above).
No / Yes
171 Event Counter is momentarily suspended? - Event Counter 3 should be momentarily suspended? If not then it will be active.
The allowed answer is either: 0 (No: active) or: 1 (Yes: suspended).
No / Yes
COUNTER N. 4
172 Load-value Event-Counter n. 4: this is either the number of units, or the distance in metres, or the time in seconds, or the cost of the fare, or the cost of the extra charges
that should be counted for the tariff-block to be changed. The allowed value goes from 0 (min) to 65535 (max). The tariff-block to change to is to be programmed in Q.173.
0 - 65535
173 Block-Number (abs) at event n. 4: this is the block number (absolute) to be used when the event occured that has been programmed in Q.172. The allowed value goes
from 0 (min) to 62 (max). Also allowed is the value 255; In this case, instead of using a new block number, the former block number is used again.
0 - 255
174 Block-Offset (rel) at event n. 4: this is the block offset (relative) to be used when the event occured that has been programmed in Q.172. The relative block offset is the
number of blocks to add to the current block number in order to obtain the new block number. The allowed value goes from 0 (min) to 62 (max).
0 - 64
175 Load-value is Units? - Is the parameter programmed in Q.172 for event counter 4 the number of units? No / Yes
176 Load-value is Distance (in metres)? - Is the parameter programmed in Q.172 for event counter 4 the distance in metres? No / Yes
177 Load-value is Waiting-Time (in seconds)? - Is the parameter programmed in Q.172 for event counter 4 the waiting-time in seconds? No / Yes
178 Load-value is Cost of Fare? - Is the parameter programmed in Q.172 for event counter 4 the cost of the fare? No / Yes
179 Load-value is Cost of Extra-Charge? - Is the parameter programmed in Q.172 for event counter 4 the cost of the extra-charge? No / Yes
180 Reload every Metre? (if not: every Second) - Event Counter 4 must be reloaded every metre? If not then it will be reloaded every second.
The allowed answer is either: 0 (No: every second) or: 1 (Yes: every metre).
No / Yes
181 Act. Only Above cross-speed? (if not: Allw.) - Event Counter 4 should be activated only above the cross-speed? If not then it will allways be activated. The allowed
answer is either: 0 (No: always) or: 1 (Yes: only above).
No / Yes
182
Event-Counter n.4 is moment. suspended? - Event Counter number 4 should be momentarily suspended? If not then it will be active.
The allowed answer is either: 0 (No: active) or: 1 (Yes: suspended).
No / Yes
183
At tariff-change discard accumul. Dist/Time? - If the tariff is changed manually with key K1 should the accumulated distance or time be discarded?
If not, the accumulated distance or time will be proportionaly accounted for. The allowed answer is either: 0 (No: account for) or: 1 (Yes: discard).
No / Yes
184
At tariff-change synchronize with next unit? - If the tariff is changed manually with key K1 should the current unit be completed with the current
parameters? If not, the tariff-change will be immediate. The allowed answer is either: 0 (No: immediate) or: 1 (Yes: synchronize).
No / Yes
185
Extra-Charge n. 4 is a discount? - Extra-Charge n. 4, as programmed in Q.27, should be interpreted not as an extra-charge but as a discount? The discount can only be
used as a percentage. Therefore the parameter of Q.31 should be programmed as Yes. The allowed answer is either: 0 (No: extra-charge) or: 1 (Yes: discount).
No / Yes
186
In ForHire disable keys K1, K2, K3 and K4? - In ForHire the keys K1, K2, K3 and K4 should be disabled? In case of Yes the taxi-meter works normaly including the OP-
key but all functions that can be invoked with the keys K1, K2, K3 and/or K4 are inhibited.
The allowed answer is either: 0 (No: enabled) or: 1 (Yes: disabled).
No / Yes
187
Start-of-Fare time is used for Night/Holiday extras? - Should the time in which the fare starts be considered for the calculation of the night and/or holiday extras? In case
of Yes and if there is a change from night/holiday time to normal time (or vice versa) during the trip then for as long as the trip lasts the fare cost will be calculated as if it is
still night/holiday time. Starting from the next fare the parameters for normal time will be used.
The allowed answer is either: 0 (No) or: 1 (Yes).
No / Yes
188
Show fare and extra-charge divided by 100? - Should the fare and the extra-charge be shown on their resp. displays divided by 100?
In this way the two least significant digits (usually zero) are not shown. The allowed answer is either: 0 (No: show normal) or: 1 (Yes: show divided by 100).
No / Yes
189
Available for any possible software extension
190
In case Night/Holiday extras are added on Flag drop, have to be added also on Min. trip amount?
No / Yes
191
On Euro conversion apply the Arround function?