Nr. Functions Value
220 Block-number for taxi-light to be ON: this is the number of the tariff-block where the taxi-light should be ON. The allowed value goes from 0 (min) to 62 (max). 0 - 62
221 Prog-Date-number for taxi-light to be ON: this is the number of the Prog-Date where the taxi-light should be ON. The allowed value goes from 0 (min) to 8 (max). 0 - 8
222 State of taximeter for taxi-light to be ON - This is the state (or states) of the taximeter in which the taxi-light should be ON.
The allowed values are: 0 (none) - 32 (Hired) - 64 (Stopped) - 128 (ForHire).
Also combinations are allowed. In that case the values need to be summed together.
For example, to put ON the taxi-light in Stopped and also in ForHire the value to program is: 64 + 128 = 192.
For Hire = 128
Stopped = 64
Hired = 32
None = 0
LIGHT N. 1
223 Enable light n. 1 ON in day-time? - Should it be possible for light number 1 to be ON during the day-time?
The allowed answer is either: 0 (No: disabled) or: 1 (Yes: enabled).
No / Yes
224 Light n. 1 must flash? - If Yes light number 1 will flash. The allowed answer is either: 0 (No: no flash) or: 1 (Yes: flash). No / Yes
225 Light n. 1 must go ON in overspeed? - If Yes then light number 1 will go ON in case the actual velocity is higher than the velocity programmed in Q.200. The allowed
answer is either: 0 (No: OFF) or: 1 (Yes: ON).
No / Yes
226 Light n. 1 must go on below overspeed? No / Yes
from Q 227/ available for any possible software extension / to Q 229
230 Light n. 1 ON in this tariff-block? - With Yes light number 1 will go ON in the corrisponding tariff-block.
The allowed answer is either: 0 (No: OFF) or: 1 (Yes: ON).
No / Yes
231 Block-number for light n. 1 ON: this is the number of the tariff-block where light number 1 should be ON.
The allowed value goes from 0 (min) to 62 (max).
0 - 64
232 Prog-Date-number for light n. 1 ON: this is the number of the Prog-Date where light number 1 should be ON.
The allowed value goes from 0 (min) to 8 (max).
0 - 8
233 State of taximeter for light n. 1 ON: this is the state (or states) of the taximeter in which the light number 1 should be ON.
The allowed values are: 0 (none) - 32 (Hired) - 64 (Stopped) - 128 (ForHire).
Also combinations are allowed. In that case the values need to be summed together.
For example, to put ON light number 1 in Stopped and also in ForHire the value to program is: 64 + 128 = 192.
For Hire = 128
Stopped = 64
Hired = 32
None = 0
LIGHT N. 2
234 Enable light n. 2 ON in day-time? Should it be possible for light number 2 to be ON during the day-time?
The allowed answer is either: 0 (No: disabled) or: 1 (Yes: enabled).
No / Yes
235 Light n. 2 must flash? - If Yes light number 2 will flash. The allowed answer is either: 0 (No: no flash) or: 1 (Yes: flash). No / Yes
236 Light n. 2 must go ON in overspeed? - If Yes then light number 2 will go ON in case the actual velocity is higher than the velocity programmed in Q.200. The allowed
answer is either: 0 (No: OFF) or: 1 (Yes: ON).
No / Yes
237 Light n. 2 must go on below overpseed? No / Yes
from Q 238 / available for any possible software extension / to Q 240
241 Light n. 2 ON in this tariff-block? - With Yes light number 2 will go ON in the corrisponding tariff-block. The allowed answer is either: 0 (No: OFF) or: 1 (Yes: ON). No / Yes
242 Block-number for light n. 2 ON: this is the number of the tariff-block where light number 2 should be ON. The allowed value goes from 0 (min) to 62 (max). 0 - 62
243 Prog-Date-number for light n. 2 ON: this is the number of the Prog-Date where light number 2 should be ON. The allowed value goes from 0 (min) to 8 (max). 0 - 8
244 State of taximeter for light n. 2 ON: this is the state (or states) of the taximeter in which the light number 2 should be ON.
The allowed values are: 0 (none) - 32 (Hired) - 64 (Stopped) - 128 (ForHire).
Also combinations are allowed. In that case the values need to be summed together.
For example, to put ON light number 2 in Stopped and also in ForHire the value to program is: 64 + 128 = 192.
For Hire = 128
Stopped = 64
Hired = 32
None= 0
LIGHT N. 3
245 Enable light n. 3 ON in day-time? - Should it be possible for light number 3 to be ON during the day-time?
The allowed answer is either: 0 (No: disabled) or: 1 (Yes: enabled).
No / Yes
246 Light n. 3 must flash? - If Yes light number 3 will flash. The allowed answer is either: 0 (No: no flash) or: 1 (Yes: flash). No / Yes
247 Light n. 3 must go ON in overspeed? - If Yes then light number 3 will go ON in case the actual velocity is higher than the velocity programmed in Q.200. The allowed
answer is either: 0 (No: OFF) or: 1 (Yes: ON).
No / Yes
248 Light n. 3 must go on below overspeed? No / Yes
from Q 249 / available for any possible software extension / to Q 251
252 Light n. 3 ON in this tariff-block? - With Yes light number 3 will go ON in the corrisponding tariff-block. The allowed answer is either: 0 (No: OFF) or: 1 (Yes: ON). No / Yes
253 Block-number for light n. 3 ON: this is the number of the tariff-block where light number 3 should be ON. The allowed value goes from 0 (min) to 62 (max). 0 - 62
254 Prog-Date-number for light n. 3 ON: this is the number of the Prog-Date where light number 3 should be ON. The allowed value goes from 0 (min) to 8 (max). 0 - 8