DIGITALCONTROLINCORPORATED
DigiTrak Falcon F5
®
Operator's Manual 63
Above Ground (Pre-Bore) Tilt Method
Do not roll the transmitter more than two clock positions (CP) during this procedure.
1. Place the transmitter on an approximately level surface (0±10°) for at least five seconds
with the receiver at the Locate screen and transmitter data being displayed.
2. Tilt the transmitter up at approximately 65° (over 100%, or nearly vertical).
3. Hold the transmitter steady for 10–18 seconds.
4. Return the transmitter to level within 10 seconds.
5. After 10–18 seconds, all transmitter data disappears from the receiver’s screen, indicating the
transmitter frequency has changed.
6. Select the new frequency band in the receiver's Band Selection menu.
The new band displays at the top of the Main menu. It may take up to 30
seconds for the transmitter to begin sending data on the new frequency;
return to the Locate screen and verify that transmitter data appears on the
display.
Band Selection Menu
Page28
Below Ground (Mid-Bore) Roll Methods
Switching between bands on the Falcon F5 transmitter may provide better data results while drilling in a
section of the bore with a high level of interference. Use these methods to switch between transmitter
frequency bands mid-bore. Practice these roll methods before sending the drill head below ground.
Frequency Change, 10-2-7
1. Ensure roll offset is disabled and transmitter roll data is displayed on the
receiver.
Roll Offset Menu
Page22
2. Position the transmitter at 10:00 (±1 clock position, or CP) for 10–18 seconds.
3. Roll the transmitter clockwise to its 2:00 position (±1 CP) within 10 seconds and remain there for
10–18 seconds.
4. Roll the transmitter clockwise to its 7:00 position (±1 CP) within 10 seconds.
5. When transmitter data disappears from the receiver, the transmitter frequency has changed. This
will take approximately 10–18 seconds.
6. Select the new frequency band in the receiver's Band Selection menu.
The new band displays at the top of the Main menu. It may take up to 30
seconds for the transmitter to begin sending data on the new frequency;
return to the Locate screen and verify that transmitter data appears on the
display.
Band Selection Menu
Page28
7. Re-enable roll offset, if applicable.
Frequency Change, Repeating Roll Sequence (RRS3)
1. Remain at any clock position (CP) for at least 40 seconds to clear all timers.
2. Make a reference mark on the drill string.
3. Complete one full clockwise rotation (±2 CP) of the reference mark within 0.5–30 sec., then wait
10–20 seconds.
4. Repeat step 3 two more times, for a total of three rotations (RRS3).
5. After the third rotation, leave the drill string at rest for a total of 60 seconds, after which the
transmitter changes frequency.