8 9
ENEN
MENU & KEYS MENU & KEYS
Advanced
Numerous parameters can be adjusted or set in the advanced menu.
Advanced keys
OFF/MODE
By pressing briey and repeatedly on the OFF/MODE key, you can select:
Lights permanent off > light is always off.
Lights permanent on > light is always on.
Lights by timer > light goes on/off via the timer.
Lights by countdown > light goes on/off by countdown (asynchronous times, e.g., 10/10 or 11/11)
Lights control as slave invert > If you use two rooms and two maxi controllers, two or more maxi
controllers can communicate with each other by means of a connection between ports ABP on the controllers.
A four-core communication cable should then be placed between these two ports. If ‘slave invert’ is selected, the
light in Room 1 (for example) switches OFF when the light in Room 2 goes ON and vice versa. The slave controller
copies the date, time, timer, countdown and rise/fall of the master controller.
Lights control as slave copy > This function is similar to the previous function except that now the light in room
2 operates at the same time as the light in room 1. Several controllers using different slave settings can be connected in
this manner. E.g., 2 “slave invert” and 3 “slave copy”. If several rooms are used simultaneously, the clock runs the same
time everywhere.
ESCAPE
By pressing briey and repeatedly on the ESCAPE key, you can select to show:
LICHT The current time, room temperature, light output and remaining time are displayed.
CO2 The current and set CO2 value are displayed.
AUX/FAN The current temperature and the set fan speed are displayed.
VPD The plant temperature, room temperature, relative humidity and the VPD are displayed.
High/low records All high/low values of the connected sensors are displayed here.
Using the + and – keys, the values of the different sensors can be displayed including when the
maximum/minimum event has occurred.
Events/alarm log Here you can see when and why the controller has intervened.
PLUS (+) key
You can browse or increase the values by pressing this key briey and repeatedly.
MIN (-) key
You can browse or decrease the values by pressing this key briey and repeatedly.
SET key
Using this key, the menu is opened in order to change settings.
Advanced light menu
12:38 27°3C 1200
day 7:22 1200
The menu will open by pressing the SET key while the Light screen is displayed. Using the + and – keys, you can
navigate through the various parameters in the menu. The following parameters can be set in the Light menu:
Time
Time (clock)
16:17
The current time can be set by pressing the SET key while TIME is displayed on the screen. For this purpose, use the +
and – keys and conrm with SET.
Date
Date (d-m-y)
09-12-2015
The current date can be set by pressing the SET key, while DATE is shown on the screen. For this purpose, use the +
and – keys and conrm with SET.
Timer on/off
Timer on/off
00:00 till 22:00
The precise time that the light has to go on or off can be set by pressing the SET key while TIMER is displayed on the
screen. For this purpose, use the + and – keys and conrm with SET.
Countdown
Countdown on/ off
10 / 10 hours
The time that the light has to go on or off can be set by pressing the SET key while COUNTDOWN is displayed on the
screen. Asynchronous times, which can reduce a cycle can be set with this parameter.
Rise/fall
Rise / Fall time
0 / 0 minute
Sunrise and/or sunset can be simulated using rise/fall. The time, which indicates how long the simulated sunrise or
sunset should last can be set by pressing the SET key while Rise/Fall is displayed.
Temp limit
Temp limit L/H/S
30°C/32°C/34°C
Three temperatures are displayed: L, H and S. When the rst temperature (L = Low-Dim) is reached, the lights dim to
prevent the temperature from becoming too high in the room. The controller dims the lights up to maximum 35%.