When the second temperature (H = High-Dim) is reached despite the dimmed lights, the controller switches off all lights
operated by the even ports (2 and 4). Half of the lights are therefore turned off.
When the third temperature (S = Shut-down) is reached despite the fact that all lights are dimmed and half of the lights
are off, all lights go off. Then there is probably a problem with the air conditioning in the room.
The temperature limits can be altered by pressing the SET key.
Temp-offset
Temp offset
# 0.0 °C
The value of the room temperature sensor can be changed/adjusted or calibrated by pressing the SET key while TEMP-
OFFSET is displayed on the screen. For this purpose, use the + and – keys and conrm with SET.
Output power
You can select which light xture/ballast must be controlled by pressing the SET key while OUTPUT POWER is displayed
on the screen. Using the + or – key you can select:
315watt (cdm)
400watt
600watt
600watt EL UHF
630watt DUAL (cdm)
1000watt EL UHF
Set output power
1000 Watt EL UHF
Select the correct lling/ballast output and conrm with SET.
After powerfail
After powerfail
Continue
In case of a power failure, you can opt for leaving the lights off or for switching the lights back on after the power supply
has been restored. Using the + and – keys, opt for CONTINUE or HOLD and conrm with SET.
LCD back light
LCD back light
ON
By pressing the SET key while LCD back light is displayed on the screen, you can opt to have the LCD screen displayed
continuously or to switch it on only when a key is pressed. Using the + and - keys, opt for always ON or AUTO OFF
and conrm with SET.
Temperature display
Temperature
in Celsius
Here you can select the temperature display in either Celsius or Fahrenheit. Press on the SET key and using the + and
– keys, select Fahrenheit or Celsius and conrm with SET.
Output display
Output display
in Watt
You can select to display the status of dim/boost in the Light screen in Watt or in percentages. Press on the SET key and
using the + and – keys, select Watt or percentage and conrm with SET.
Dual room off
Dual room
OFF
With this option, two rooms can be controlled with one controller. OUT1 is room 1 and temp sensor 1 and OUT2 is
room 2 and temp sensor 2. If the lights are turned on in room 1, they will be turned off in room 2.
Advanced CO2 menu
CO2 SMARTLOGIC2
The new EVO 1.2 Maxi Controller automatically adjusts the best possible CO2 dosing using a special algorithm that
prevents the values being exceeded and always keeps the CO2 level as stable as possible. This self learning program
also ensures that no harmful CO is released by CO2 gas generators, due to the rapid on and off switching of the
burner. It is possible that CO2 dosages are given that may appear to be "foreign" and illogical to the user. Thee
controller does this during the learning mode. This is normal.
CO2 cur 858ppm:
CO2 setp 870pp
Press briey on the SET key in the CO2 display screen to open the CO2 menu. Use the + and - keys to navigate through
this menu.
Auto calibrate
CO2 auto calibrate
The auto calibrate function sets the value automatically to 400 ppm if the sensor is located in outdoor air. Put the sensor
for 5 minutes in outdoor air, press on the SET key and select AUTO CALIBRATE Yes or No. Conrm by pressing the
SET key.