12 13
ENEN
MENU & KEYS MENU & KEYS
Manual calibrate
co2 manual calib
0 ppm
You can also select to calibrate the sensor manually.
Pressing briey on the SET key will open the menu. Press the SET key once more when CO2 calibrate is displayed.
Here you can adjust the value. If the sensor indicates 440 ppm for example in outdoor air, you calibrate the sensor by
lling in –40 ppm using the + and – keys.
CO2 mode
You can opt to add or remove CO2 (air quality in living accommodation).
CO2 Addition is selected if CO2 needs to be added.
CO2 Removal is selected if CO2 needs to be removed. This is mandatory in public buildings.
Start dosing time
Start dosing tim
0 minutes
To deal with gas/CO2 more efciently, you can opt for dosing the CO2 after the lights come on. By pressing the SET
key and using the + and – keys, you can select the interval in minutes between lights on and dosing of CO2.
Stop dosing time
Stop dosing tim
0 minutes
To deal with gas/CO2 more efciently, you can opt for stopping the CO2 dosing before the lights go off. You can
select the interval in minutes between stopping the CO2 dosing and lights off by pressing the SET key.
CO2 night heater
CO2 night heater
setpoint 22°
A room can also be heated by the CO2 generator if the power supply is limited.
The night temperature can be set by pressing the SET key.
Take note Ensure sufcient supply of fresh air to the room. Poor burning can cause the release of toxic
gases that are harmful to people, animals and plants. The ame must always burn with a blue colour.
Advanced aux/fan menu
Eight parameters can be set in the advanced fan menu in order to ensure that the installation works as efciently as
possible.
Temperature
RH Day
RH Night
Max fan speed Day
Max fan speed night
Min fan speed
De aux setting Heat
De aux setting RH
Press SET once and use the + and- keys to select the above options.
Press SET once more to change these parameters.
The fan mode can be changed by pressing the SET key twice. The fan mode determines when the fan control becomes
active. It is possible to choose between the following options:
Temperature > the fan works faster if a pre-set temperature is reached.
Temp day/dehumidify night > The fan works faster if a pre-set temperature is reached during the day and during the
night if a pre-set relative humidity is reached.
Dehumidify day/night > The fan works faster if a pre-set relative humidity is reached. A different value can be set for
the day than for the night.
Manual > the fan is set manually to a set speed.
The temperature mode can be used to set the temperature at which the fan must work faster.
The RH day mode can be used to set the maximum humidity during the day.
(Only visible if the fan mode dehumidify is selected)
The RH night mode can be used to set the maximum humidity during the night.
(Only visible if the fan mode dehumidify is selected)
Max speed day can be used to set the maximum fan speed during the day.
Max speed night can be used to set the maximum fan speed during the night.
The min. speed mode can be used to set the minimum fan speed.
(Some fans or ventilators cannot be dimmed by more than 30%). Always check for a draught and whether the fan is
working.
The aux settings for temperature
The aux settings for relative air humidity