Questions and Answers

  • S
    Shari LopezSep 15, 2025
    Why does the power cord get warm on my Dimplex DF2426?
    • T
      Troy AtkinsonSep 15, 2025
      It's normal for the power cord of your Dimplex Indoor Fireplace to get slightly warm when the heater is on. However, if the cord gets hot to the touch, it could indicate a defective power cord that needs to be replaced.
  • N
    Noah BarronAug 25, 2025
    Is it normal for the power cord to get warm on my Dimplex Indoor Fireplace?
    • T
      Teresa Alvarez DDSAug 25, 2025
      A warm power cord on your Dimplex Indoor Fireplace can be normal when the heater is on. However, if the cord gets hot to the touch, it indicates a defective power cord, and you should replace it.
  • J
    Jennifer RiddleAug 25, 2025
    What to do if my Dimplex DF2426 Indoor Fireplace does not turn on manually?
    • K
      Kayla CareyAug 26, 2025
      If your Dimplex Indoor Fireplace is not turning on manually, it could be due to several reasons. First, ensure proper operation. Second, check the fuse/breaker panel to make sure there is incoming power from the electrical wall socket. Third, the 3-position switch may be defective and need replacement. Finally, the Remote Control Receiver could be defective, so you should replace it and initialize the Remote Control and Receiver.
  • K
    Kenneth PageAug 26, 2025
    Why does my Dimplex Indoor Fireplace turn on and off by itself?
    • D
      Duane ConnerAug 27, 2025
      If your Dimplex Indoor Fireplace turns on or off by itself, it might be due to a few reasons. The remote control may have a similar frequency to other remotes in the area, in which case you should replace the remote control and initialize it to the Remote Control Receiver. Also, there could be radio frequency disturbance from outside sources, requiring replacement of the Remote Control and Remote Control Receiver, followed by initialization. Lastly, a defective Remote Control Receiver can cause this issue, so replacing it and initializing the Remote Control and Receiver may resolve the problem.
  • E
    Eric JonesSep 16, 2025
    Why is my Dimplex DF2426 making excessive noise when the heater is on?
    • B
      Barbara LopezSep 16, 2025
      If there is excessive noise when the heater is on in your Dimplex Indoor Fireplace, it could be due to a dirty Heater Assembly. Ensure that the exterior intake louvers and firebox cavity are free of dirt and dust. Another possibility is a defective Heater Assembly, which would need to be replaced.
  • L
    Lawrence BaxterSep 23, 2025
    Why is the log set dim in my Dimplex Indoor Fireplace BF9000?
    • T
      Tracy SweeneySep 23, 2025
      If the log set in your Dimplex Indoor Fireplace (BF9000 model) is dim and not glowing, check the wiring connections for any looseness. It could also be due to a defective LED Log Driver Board or a defective Log Set Assembly, both of which would need to be replaced.
  • A
    antoniojensenSep 8, 2025
    What causes the flame shutter to malfunction on my Dimplex DF2426 Indoor Fireplace?
    • M
      Matthew HowellSep 8, 2025
      If the flame shutter is not working on your Dimplex Indoor Fireplace, it could be due to a defective Flicker Motor, which needs to be replaced.
  • K
    Kara MitchellSep 8, 2025
    Why is light leaking around the log set of my Dimplex DF2426?
    • C
      Carol BrownSep 9, 2025
      If you notice light leaking around the log set of your Dimplex Indoor Fireplace, it is likely that the log set is not positioned properly. Check the log set for proper fit.
  • D
    David BentonSep 2, 2025
    Why does the heater fan run continuously on my Dimplex DF2426?
    • G
      Gina StewartSep 2, 2025
      If the heater fan in your Dimplex Indoor Fireplace runs continuously, it could be due to a defective Heater Switch, a defective Thermostat, or a defective Heater Assembly. In each case, the suggested solution is to replace the defective part.
  • A
    Albert WilliamsAug 31, 2025
    Why does my Dimplex DF2426 heater emit an odor?
    • J
      jasonrushAug 31, 2025
      If your Dimplex Indoor Fireplace heater emits an odor, it is often normal when the heater is initially turned on, as it burns off dust accumulated during manufacturing or operation. However, it can also indicate a defective Heater Assembly, which would need replacement.

Dimplex DF2426 Specifications

General IconGeneral
ModelDF2426
Product TypeElectric Fireplace
StyleTraditional
Fuel TypeElectric
Voltage120V
Wattage1500W
Heating Area400 sq. ft.
Remote ControlYes
Adjustable ThermostatYes
MaterialMetal and Glass