Owners Manual
Model
DF2524L
DF2524G
6908921359
6908921459
IMPORTANT SAFETY INFORMATION: Always read this manual rst
before attempting to install or use this replace. For your safety, always
comply with all warnings and safety instructions contained in this manual
to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com

Other manuals for Dimplex DF2524G

Questions and Answers

  • N
    Norma MccartySep 3, 2025
    Why is the heating element in my Dimplex DF2524G Indoor Fireplace glowing red?
    • J
      jillthompsonSep 4, 2025
      If the heating element in your Dimplex Indoor Fireplace is glowing red, small glowing sections are considered normal. However, if larger glowing sections are causing the heater to trip the thermal cutout, unplug the unit, discontinue use, and replace the heater assembly.
  • M
    Michael SerranoSep 18, 2025
    Why is my Dimplex DF2524G so noisy when the heater is on?
    • G
      Gregory DavisSep 18, 2025
      If there's excessive noise when the heater is on in your Dimplex Indoor Fireplace, it could be due to a dirty heater assembly. Ensure that the exterior intake louvers and firebox cavity are free of dirt and dust. A defective heater assembly could also be the cause, requiring replacement.
  • C
    cooperdawnSep 16, 2025
    Why is the heater not turning off on my Dimplex DF2524G?
    • B
      bbauerSep 16, 2025
      If your Dimplex Indoor Fireplace heater is not turning off, ensure you are operating the unit correctly. Otherwise, a defective switchboard, thermistor, relay board, or display/control board could be the cause, requiring replacement of the respective part.
  • O
    oashleySep 14, 2025
    Why does the heater fan run continuously on my Dimplex DF2524G Indoor Fireplace?
    • Y
      Yolanda ThomasSep 14, 2025
      If the heater fan in your Dimplex Indoor Fireplace runs continuously, it indicates a defective heater on/off switch that needs to be replaced.
  • K
    Kevin EvansSep 12, 2025
    Why is the flame shuddering on my Dimplex Indoor Fireplace?
    • J
      Jorge ShepherdSep 12, 2025
      If your Dimplex Indoor Fireplace flame is shuddering, it is likely due to a defective flicker motor, which will need to be replaced.
  • R
    Rachel SmithSep 12, 2025
    Why is the flame not visible on my Dimplex Indoor Fireplace?
    • M
      michellenealSep 12, 2025
      If the flame is not visible in your Dimplex Indoor Fireplace, check for loose wiring connections. If the wiring is secure, the LED light assembly may not be working and need replacement. In some cases, a defective display/control board can also cause this issue, requiring replacement.
  • T
    Todd McdowellSep 9, 2025
    Why is the flame frozen on my Dimplex DF2524G?
    • F
      foxashleySep 9, 2025
      If the flame in your Dimplex Indoor Fireplace is frozen, it could be due to loose wiring, so check the wiring connections. Another possible cause is a defective flicker motor, which would need to be replaced.
  • I
    igoodwinSep 7, 2025
    Why is my Dimplex DF2524G making grinding noises?
    • J
      John JonesSep 7, 2025
      If you are experiencing grinding or excessive noise with the heater off in your Dimplex Indoor Fireplace, it could be caused by the flicker rod hitting or rubbing against internal components. Ensure the rod is straight and mounted properly in the bracket, spinning freely away from other components. Replace if necessary. Alternatively, a defective flicker motor could be the cause, requiring replacement.
  • V
    victoria79Sep 5, 2025
    What does “PF” mean on my Dimplex DF2524G display?
    • R
      robert31Sep 5, 2025
      If the display of your Dimplex Indoor Fireplace shows a “PF” error, it could be due to a loose connection of the thermistor, so check the wiring connection. Alternatively, the thermistor itself may be defective and require replacement.
  • N
    nleeAug 20, 2025
    Why does my Dimplex DF2524G Indoor Fireplace trip the circuit breaker?
    • M
      matthewknoxAug 20, 2025
      If your Dimplex Indoor Fireplace circuit breaker trips or a fuse blows when you turn it on, this could be due to a short in the unit's wiring, which requires tracing the wiring. Alternatively, you might be exceeding the circuit's current rating by using too many appliances on the same circuit. Try plugging the unit into a different outlet, or have a dedicated 15 amp circuit installed for the fireplace.

Dimplex DF2524G Specifications

General IconGeneral
Product TypeElectric Fireplace
Model NumberDF2524G
StyleTraditional
Fuel TypeElectric
Voltage120V
Wattage1500W
Heating AreaUp to 400 sq. ft.
ThermostatYes
Remote ControlYes
Log SetYes
FinishBlack
Flame EffectLED
Safety FeaturesOverheat protection