- 10 -
Product Clearances
WARNING:
DO NOT PLACE OBJECTS WITHIN 300mm OF THE FRONT OF THE HEATER AND
150mm EITHER SIDE
It is important to be aware of how your Quantum storage heater has been installed electrically. If you Quantum
has only one electrical connection, it must be carefully configured to work with your o-peak electricity tarri.
Available fixed charge times must be manually programmed into the heater to tell it when to charge; no external
timers or contactors are needed. Up-to 4 digital charge times can be set.
If charge times are not programmed into the heater, the default times will be used which are set-up by default to
support dual-supply installations: 00:00 – 00:00 or 24h charge window.
A 24h charge window in a single supply installation will cause the heater to charge continuously,
including times when o-peak electricity is not available, resulting in larger bills.
Single Supply
NOTE:
If electricity tarri charge times have changed, the digital charge times in the heaters settings must be
checked to ensure they match.
150
mm
150
mm
250 mm
300 mm