Meal Parameters
The Station Commander operator module has the capability of programming the carts under
its control for different rethermalization cycle lengths for each meal. This means that the
breakfast meal rethermalization cycle could be less than the dinner and lunch cycles, should
this be desirable.
In addition, an automatic hold cycle can be programmed to supply intermittent heating after
the normal rethermalization cycle is complete. This allows carts to be held for a
programmable period of time without significant loss of heat to hot food items.
The hold cycle is comprised of two parts, the “ready” time and “maintain” time. At the
completion of the rethermalization cycle, the electrical power to the Perfect-Temp cart is
switched “off”. The duration of time that the power remains “off” is known as “ready” time.
When the “ready” time duration expires, electrical power to the Perfect-Temp cart is
switched “on”. The duration of time that the power remains “on” is known as “maintain”
time. At the expiration of the “maintain” time, the power again is switched “off” for another
“ready” time. This sequence continues until the total elapsed time of both the “ready” and
“maintain” time exceeds the programmed “hold” time.
When the duration of the programmed “hold time” is exceeded, the Station Commander
automatically discontinues further activity with that particular cart and displays the “Hold
Time Exceeded” symbol.
Programming Meal Parameters
1) Press the “PROGRAM” key
2) Display will prompt:
Select:
Program Meal Times
Configure Unit
3) Use the “ “ keys to highlight “Configure Unit”.
4) Press the “YES” key to select.
5) Enter pass code “15037” on the keypad.
6) Display will prompt:
Select: System Setup
Set Meal Parameters
Set Pass codes
Set Time of Day
Reset
7) Use the “ “ keys to highlight “Set Meal Parameters”.