Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page
44
How to configure LoRawan gateway? -LoRa version
If you buy the Gateway from CNDingtek after your receiving Gateway , we have the gateway
configuration, you only need to connect the gateway power supply, and network cable.
If you receive the gateway, then you want to change the gateway IP and port number, please
refer to the relevant manuals provided by our company, or contact our technical staff.
Why User cannot See Device Data?
Considering shipping rules, devices are not connected to battery. So user should open cover
and connect battery with the PCB board. For some version with magnetic part outside,
please remove the magnetic part, then the battery will power to the sensor.
Check whether the frequency bands of the device and the gateway are the same.The
gateway frequency should work with the LoRawan module band. please configure the
sensor or gateway to make them match.
The LoRa server device data should be same as the sensor. For ABP mode, the
devaddr/nwkskey/appskey should be same as the registration information on the server.
For OTAA mode, the deveui, appeui should be same as the registration.
Shorten distance between sensor and gateway
Some LoRa server, like TTN (the things network) ask for special devaddr. Please use TTL
UART to connect with sensor and change the parameter.
Please check whether the gateway is correctly connected to the network server.
Please check the position of the jumper cap, whether the jumper is on the solid position.
User receive data But is Garbled Form.
Nwkskey,appskey/port error If port, nwkskey, appskey is error. The data will be messed
that user can not directly read the data.
Please contact with CNDingtek to receive the updated protocol which is disclosed after NDA
signed.
How to Test and Install Devices?
Please refer to the relevant manual or we can provide you with the relevant video.
How to modify LoRa module parameters
Please refer to LoRa configuration section in "DF702 Configuration Manual.
How to modify the data upload time,full height alarm value parameters?
Please refer to the "Device Parameter Configuration" in the "DF702 Configuration Manual.
Where User can monitor Device Data ?
For the LoRa version
Form gateway and the Network Server are required. The device sends the data to the
gateway. The gateway forwards the data to the network server . The data can be seen on the
network server and the data is forwarded to the application server . If necessary, we can
provide the corresponding gateway the application server and application server or data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dingtek DF702 and is the answer not in the manual?

Dingtek DF702 Specifications

General IconGeneral
BrandDingtek
ModelDF702
CategoryControl Unit
LanguageEnglish