Data Time Intervals
For example Test time data every 10 minutes, when a change of state is detected the data
will be upload, the state remains unchanged in next intervals, and no data will be uploaded.
The data will be uploaded periodically like as heartbeat the data interval default 4 hours can
be modified, specific reference to the agreement.
State change means:
From full to not from
Not from to full
Whether the
data will be
reported
immediately
when the
alarm
condition is
reached
Check if the
Trash bin is
full
The Device will detect
the Distance between
sensor and garbage if
this Distance is more
Then 30cm no alarm
if less than 30 cm
alarm will be
activated.
Detect if a
fire has
been
occurred
75℃
(Can be
modified above
75℃
Fire alarm will
be activated )
Detected temperature
is less than 75℃
above this
Temperature sensor
will activate the
alarm.
Check
whether the
trash Bin
can fallen
any side
This feature is
available in enhanced
version not in
slandered version.
Check if the
battery is
about to run
out
It will detect the
power of battery
more than 20% no
alarm less than 20%
alarm will be
activated.