EasyManuals Logo

Dini Argeo DGT4X User Manual

Dini Argeo DGT4X
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
QSG_ENG_DGT4X
Data Register DESCRIPTION
Status register
scale 1
40202
Bit 15
(msb)
...
Bit 8
(lsb)
No function.
Bit 7
(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(lsb)
Tare PT (1 = PT tare is active).
Tare (1 = Tare is active).
Net Weight Polarity (0 = “+”; 1 = “-”).
1 = Scale unloaded (gross weight = 0).
Overload condition (0 = No; 1 = overload).
Underload condition (0 = No; 1 = underload).
Stability (0 = “unstable”; 1 = “stable”).
Gross Weight Polarity (0 = “+”; 1= “-”).
Gross weight
scale 1
40203
Gross Weight of scale 1.
40204
Status register
scale 2
40205 Same as Status register scale 1.
Gross weight
scale 2
40206
Gross Weight of scale 2.
40207
Status register
scale 3
40208 Same as Status register scale 1.
Gross weight
scale 3
40209
Gross Weight of scale 3.
40210
Status register
scale 4
40211 Same as Status register scale 1.
Gross weight
scale 4
40212
Gross Weight of scale 4.
40213
Net weight
scale 1
40214
Net Weight of scale 1.
40215
Net weight
scale 2
40216
Net Weight of scale 2.
40217
Net weight
scale 3
40218
Net Weight of scale 3.
40219
Net weight
scale 4
40220
Net Weight of scale 4.
40221
Data Register DESCRIPTION
Status register
scale 1
40202
Bit 15
(msb)
...
Bit 8
(lsb)
No function.
Bit 7
(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(lsb)
Tare PT (1 = PT tare is active).
Tare (1 = Tare is active).
Net Weight Polarity (0 = “+”; 1 = “-”).
1 = Scale unloaded (gross weight = 0).
Overload condition (0 = No; 1 = overload).
Underload condition (0 = No; 1 = underload).
Stability (0 = “unstable”; 1 = “stable”).
Gross Weight Polarity (0 = “+”; 1= “-”).
Gross weight
scale 1
40203
Gross Weight of scale 1.
40204
Status register
scale 2
40205 Same as Status register scale 1.
Gross weight
scale 2
40206
Gross Weight of scale 2.
40207
Status register
scale 3
40208 Same as Status register scale 1.
Gross weight
scale 3
40209
Gross Weight of scale 3.
40210
Status register
scale 4
40211 Same as Status register scale 1.
Gross weight
scale 4
40212
Gross Weight of scale 4.
40213
Net weight
scale 1
40214
Net Weight of scale 1.
40215
Net weight
scale 2
40216
Net Weight of scale 2.
40217
Net weight
scale 3
40218
Net Weight of scale 3.
40219
Net weight
scale 4
40220
Net Weight of scale 4.
40221
16.2 MODBUS REGISTERS  ind.ch (4 SCALES)
This manual contains the main registers for reading data / sending commands.
Refer to the Modbus protocol manual for the complete list of available registers.

Other manuals for Dini Argeo DGT4X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dini Argeo DGT4X and is the answer not in the manual?

Dini Argeo DGT4X Specifications

General IconGeneral
BrandDini Argeo
ModelDGT4X
CategoryTransmitter
LanguageEnglish

Related product manuals