EasyManuals Logo

Dini Argeo DGT4X User Manual

Dini Argeo DGT4X
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
6
7
8
888888
888888
div.deC
div.deC
...
Cel.Cap
div.deC
Cel.sen
dead.ld
CELL 4
CELL 3 CELL 2 CELL 1
PWR INPUT 485RELAYS ANALOG 232
g
kg
lb
NET
0
~
F
W1
SP1
W2
SP2
35
EXC -
EXC +
34
SIG -
29
SIG +
28
SIG -
25
SIG +
24
EXC -
23
REF -
21
REF
20
SIG -
19
SIG +
18
26
EXC +
22
EXC +
+
EXC +
30
EXC -
31
SIG +
32
SIG -
33
EXC -
27
24Vdc
Earth
1
RL 1
6
RL 2
7
5
IN 1
4
COM
3
2
COM
8
GND
IN 2
I -
10
I +
9
GND
15
A +
16
14
TX
13
V -
12
11
B -
17
V +
RX
ZERO TARE MODE PRINT
g
kg
lb
NET
0
~
F
W1
SP1
W2
SP2
CELL 4
CELL 3 CELL 2 CELL 1
PWR INPUT 485RELAYS ANALOG 232
g
kg
lb
NET
0
~
F
W1
SP1
W2
SP2
35
EXC -
EXC +
34
SIG -
29
SIG +
28
SIG -
25
SIG +
24
EXC -
23
REF -
21
REF
20
SIG -
19
SIG +
18
26
EXC +
22
EXC +
+
EXC +
30
EXC -
31
SIG +
32
SIG -
33
EXC -
27
24Vdc
Earth
1
RL 1
6
RL 2
7
5
IN 1
4
COM
3
2
COM
8
GND
IN 2
I -
10
I +
9
GND
15
A +
16
14
TX
13
V -
12
11
B -
17
V +
RX
ZERO TARE MODE PRINT
g
kg
lb
NET
0
~
F
W1
SP1
W2
SP2
6
7
div.deC
...
div.deC
div.deC
CapaC
QSG_ENG_DGT4X
Complete menu
at page 4
6. Maximum scale capacity, increment and decimal point setting
Set the decimal point position and the minimum scale increment*
1
( 0,001 - 0,002 - 0,005 - 0,01 - 0,02 - 0,05 - 0,1 - 0,2 - 0,5 - 1 - 2 - 5 - 10 - 20 - 50 ).
Set the maximum scale capacity*
2
(max 999999 ).
Examples:
7. Theoretical calibration
Set the total load cells capacity (up to 999999).
Set the load cells sensitivity (up to 999999).
(mV/V cell1) + (mV/V cell2) + (mV/V cell3) + (mV/V cell4)
(mV/V cell1) + (mV/V cell2) + ... + (mV/V celln)
n
Insert in
Cel.sen
parameter, the load cells sensitivity
sum value:
For each scale to calibrate, insert in
Cel.sen
parameter the
average sensitivity value of the load cells:
Dead load weight (from -9999.9 to 99999.9).
*
1
Increment = the amount that the scale will increment by as weight is added or removed.
*
2
Maximum capacity = the maximum weight that can be measured using the scale you are creating.
1.
Set
div.deC
and
CapaC
(ch. 4).
2.
Set in
Cel.Cap
the total load cells
capacity (sum of the nominal load cell
capacities).
3.
Set in
Cel.sen
the theoretical signal
value of the load cells.
4. Enter in
dead.ld
step. The display
shows the theoretical dead load
value. Modify the value and/or confirm
with
.
5.
Save calibration (Press key many
times until
save?
message will
appear, then press
to confirm).
For a 60000 kg scale, with 2 kg
increment:
div.deC = 2
CapaC = 60000
For a 10000 g scale, with 0,1 g increment:
div.deC = 0,1
CapaC = 10000,0
For a 3000 kg scale, with 0,05 kg
increment:
div.deC = 0,05
CapaC = 3000,00
MODE 1 “DEP.CH”
MODE 2 “IND.CH”

Other manuals for Dini Argeo DGT4X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dini Argeo DGT4X and is the answer not in the manual?

Dini Argeo DGT4X Specifications

General IconGeneral
BrandDini Argeo
ModelDGT4X
CategoryTransmitter
LanguageEnglish

Related product manuals