13
USING THE GENERATOR
Service environment of the generator
1
Applicable temperature: -5°C ~ 40°C (23°F ~ 104°F);
Applicable humidity: below 95%;
Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m).
Standard atmospheric condition
Ambient temperature Tr: 298k (25°C)(77°F)
Relative air humidity Ɏr: 30%
Absolute atmospheric pressure Pr: 100kPa
When actual environmental condition is inconsistent with the condition of output power of the generator
set:
Every 5°C(41°F) of increase in ambient temperature will reduce the power of generator by about 2%.
Every 30% of increase in relative humidity of air will reduce the power of generator by about 1.5%.
Every 300 m rising of ASL will reduce the power the generator by about 4.5%.
Generator wiring
2
When the generator is connected to household power source as a backup power supply, the connection shall be
carried out by a professional electrician or a person familiar with electricity.
After connecting the load to the generator, check carefully whether electrical connection is safe and reliable.
Improper electrical connection may cause generator damage, burning or fire.
Avoid connecting this generator to commercial power outlet.
When extending the cable, be sure not to exceed its length.
60m cross-section area is 1.5mm²
100m cross-section area is 2.5mm²
The appearance of extension cable shall be protected by a layer of tough and elastic rubber cover (IEC25) or
other substitutes.