2255
99 DDoouubbllee PPuullssee LLoocckk..
Selectable 2 pulse door lock output to operate vehicle equipped with factory “deadbolt”.
Will have similar operation to that of the Double Pulse Unlock feature, but will perform the functions on the Lock
wire as opposed to the Unlock wire
1100 CCoommffoorrtt cclloossuurree ffeeaattuurree::
This feature is designed to integrate with vehicles that can close the power windows
and sunroof by holding the key in the driver door lock position, and will operate on both single input systems
and two pulses input dead bolt systems.
If programmed on the door lock output will activate the Comfort Close output for 20 seconds. This output will
begin 200mS after the final door lock output has completed regardless of the door lock programming.
If while the 20 second timer is active and closing the windows the user disarms the unit, the Comfort Close
output will immediately cease before the doors unlock.
The alarm system will not monitor the zone inputs for Bypass Notification, Warn away or Full trigger inputs until
after the 20 second timer has completed to avoid any false triggering of the system while the window are in
motion.
nnuuiissaannccee pprreevveennttiioonn cciirrccuuiittrryy
NPC™ requires that you change the way you test the system, as NPC™ will bypass an input zone for 60 minutes.
If the system “sees” the same zone trigger three times AND the triggers are spaced less than an hour apart, the
system will bypass that input zone for 60 minutes. If that zone does not attempt to trigger the system during
the 60-minute bypass period, the zone’s monitoring will begin again at the end of the hour. If it does attempt
to trigger while bypassed, the 60-minute bypass starts over again.
Disarming and rearming the system does not reset NPC™. The only way to reset NPC™ is for the 60 minutes to
pass, without a trigger, or for the ignition to be turned on. This allows the system to be repeatedly triggered,
disarmed and rearmed, and still allow NPC™ to bypass a faulty zone.
When disarming the system, 5 chirps indicate NPC is activated. The LED will report the zone that has been
bypassed. (See
Table of Zones
section of this guide.)

Other manuals for Directed Electronics Hornet 740T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Directed Electronics Hornet 740T and is the answer not in the manual?

Directed Electronics Hornet 740T Specifications

General IconGeneral
BrandDirected Electronics
ModelHornet 740T
CategoryCar Alarm
LanguageEnglish

Related product manuals