Page #16 background image
1330 Operators Manual Safety - 15
Emergency Procedures
CMW
Emergency Procedures
Before operating any equipment, review emergency procedures and check that all safety precautions have
been taken.
Electric Strike Description
When working near electric cables, remember the following:
Electricity follows all paths to ground, not just path of least resistance.
Pipes, hoses, and cables will conduct electricity back to all equipment.
Low voltage current can injure or kill. Many work-related electrocutions result from contact with less
than 440 volts.
Most electric strikes are not noticeable, but indications of a strike include:
power outage
•smoke
•explosion
popping noises
arcing electricity
If any of these occur, assume an electric strike has occurred.
Jobsite hazards could cause death or serious injury. Use
correct equipment and work methods. Use and maintain proper safety
equipment.
EMERGENCY SHUTDOWN - Release operator presence device and turn ignition switch to STOP.
Electric shock. Contacting electric lines will cause death or serious injury.
Know location of lines and stay away.