15. DEFAULT SETTING VALUES
Label Name Range °C/°F
Set
Set point LS÷US 3.0/37
Hy
Differential
0,1÷25.5°C/ 1÷ 255°F
2.0/4
LS
Minimum set point
-50°C÷SET/-58°F÷SET
-40,0/-40
US
Maximum set point
SET÷110°C/ SET ÷ 230°F
110/230
Ot
Thermostat probe calibration
-12÷12°C /-120÷120°F
0.0
OdS
Outputs delay at start up 0÷255 min 0
AC
Anti-short cycle delay
0 ÷ 50 min
1
CCt
Continuos cycle duration 0.0÷24.0h
0.0
COn
Compressor ON time with faulty
probe
0 ÷ 255 min
15
COF
Compressor OFF time with faulty
probe
0 ÷ 255 min
30
CH
Kind of action CL=cooling; Ht= heating CL
CF
Temperature measurement unit
°C ÷ °F
°C/°F
rES
Resolution
in=integer; dE= dec.point
dE/-
IdF
Interval between defrost cycles
1
÷
120 ore
8
MdF
(Maximum) length for defrost
0
÷
255 min
20
dFd
Displaying during defrost
rt, it, SEt, DEF
it
dAd
MAX display delay after defrost 0 ÷ 255 min 30
ALc
Temperat. alarms configuration
rE= related to set;
Ab = absolute
Ab
ALU
MAXIMUM temperature alarm
Set
÷
110.0°C; Set÷230°F
110/230
ALL
Minimum temperature alarm
-50.0°C
÷
Set/ -58°F
÷
Set
-50/-58
ALd
Temperature alarm delay
0 ÷ 255 min
15
dAO
Delay of temperature alarm at
start up
0 ÷ 23h e 50’
1.3
i1P
Digital input polarity oP=opening;CL=closing cL
i1F
Digital input configuration
EAL=extern. alarm; bAL=lock
regulation; PAL=press. switch;
dor=door switch; dEF=defrost;
LHt=disabled; Htr= cooling -
heating
EAL
did
Digital input alarm delay 0÷255min 5
Nps
Number of activation of pressure
switch
0 ÷15
15
odc
Compressor status with open
door:
no, Fan = normal;
CPr; F_C = Compr. OFF;
no
PbC
Kind of probe
Ptc; ntc
ntc/Ptc
rEL
Software release -- 4.0
Ptb
Map code -- -
Hidden parameters
Dixell s.r.l. Z.I. Via dell’Industria, 27
32010 Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
(PDLO GL[HOO#GL[HOOFRP KWWSZZZGL[HOOFRP
Weiss Instruments, Inc.
905 Waverly Avenue
Holtsville, New York 11742
www.weissinstruments.com
Phone: 631 207 1200 - Fax: 631 207 0900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the dixell XR20C and is the answer not in the manual?

dixell XR20C Specifications

General IconGeneral
Front ProtectionIP65
Dimensions74 x 32 x 60 mm
Resolution0.1 °C
Power Consumption3 VA max
Power Supply230V AC ±10%, 50/60Hz
Operating Temperature0 to 60 °C
Storage Temperature-30 to +80 °C
InputsNTC or PTC
Measuring RangeNTC -50 to +110°C; PTC -55 to +150°C
Accuracy±0.5 °C
Relative Humidity20 to 90% RH (non-condensing)
Display3 digits
CommunicationOptional RS485 (Modbus RTU)
Protection DegreeIP65