Operating Instructions XWA11V
dIXELV8.8-KIT
1
Weiss Instruments,LLC. 905 Waverly Ave. Holtsville
, NY 11742 631-207-1200 www.weissinstruments.com
XWA11V-KIT
Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
1. GENERAL DESCRIPTION
Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller, suitable for
temperature monitoring in a walk-in cooler or freezer. It is provided with two (2) relay outputs that supply 120 Volts to
control lights and signal an alarm. It is also provided with one (1) NTC probe input for temperature measurement. To
ease installation on existing walk-in coolers the unit has been installed in a VBOX pre-wired with an outboard buzzer,
magnetic door switch (MDS), a 9V battery harness, a pigtail harness for the unit power and the light. There is also a five
pin port that allows the user to program the parameter list with a “Hot Key”.
Note: The default settings are listed in the back of this manual. They are set for Coolers (Medium
Temp). For Freezers (Low Temp) you MUST Change the ALL and ALU settings.
See Section 4.0
We have responded to many requests to make a change in the way the light key operates. It now
overrides the Digital Input to allow a manual OFF prior to the “Lht” being exhausted.
2. GENERAL WARNINGS
2.1 PLEASE READ BEFORE USING THIS PRODUCT
This manu
al is part of the product and should be kept close to the instrument for easy and quick
reference.
The instrument shall not be used for purposes different from those described hereunder. It cannot be used
as a safety device.
Check the application limits before proceeding
.
2.2 SAFETY PRECAUTIONS **READ ME FIRST!**
Check if the supply voltage is correct before connecting the instrument.
Do not expose the back of the instrument to water or moisture: use the controller only within the operating limits
avoiding sudden temperature changes with high atmospheric humidity to prevent the formation of condensation.
Be sure to seal any J-Box with RTV sealant to prevent cold and moisture intrusion.
Warning: disconnect all electrical connections before performing any maintenance operation.
Fit the probe where it is not damaged by the end-user. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor (see address) with a detailed
description of the fault.
Consider the maximum current that can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from each other,
without crossing or intertwining or you may get bad temp readings.
(UL SPEC 0873)
The box supplied is not suitable for exterior use. If a water tight box is required contact the distributor.
Question and Answer IconNeed help?

Do you have a question about the dixell XWA11V and is the answer not in the manual?

dixell XWA11V Specifications

General IconGeneral
ModelXWA11V
TypeController
Output TypeRelay
Relay Outputs1
Protection DegreeIP20
Storage Temperature-30°C to +70°C
CommunicationRS485
Relative Humidity20...85%RH (non condensing)

Summary

General Description

General Warnings

Please Read Before Using This Product

Important safety guidelines and usage restrictions for the instrument.

Safety Precautions **Read Me First!**

Critical safety measures and warnings to prevent hazards and ensure correct operation.

Interface

Key

Explanation of individual button functions on the front panel for operation and programming.

Key Combinations: Press Simultaneously

Describes essential key combinations for navigation and mode entry.

Use of LEDs

Details the function and meaning of each LED indicator on the instrument.

Temp Alarms Setting

How to Set the Min Temperature Alarm

Procedure to configure the lower limit for temperature alarms.

How to Set the Max Temperature Alarm

Procedure to configure the upper limit for temperature alarms.

Programming

How to Change a Parameter Value Main Menu

Guide for modifying parameter values within the main programming menu.

The Hidden Menu (PR2)

Information on accessing and utilizing the advanced hidden menu for further configuration.

How to Lock the Keyboard

Steps to disable the front panel buttons to prevent accidental changes.

To Unlock the Keyboard

Procedure to re-enable the front panel buttons after locking.

Light Management

Timed Regulation: I1L = Y

Explanation of how the light operates based on timed regulation and door/sensor inputs.

Manual Override Via Light Button of XWA11V

How to manually control the light using the light button, overriding other settings.

Installation and Mounting

Mounting of XWA11V

Instructions and guidelines for physically installing the XWA11V unit and its components.

Electrical Connections

Probe Connections

Guidance on correctly connecting the temperature probe to the instrument.

Battery Back-Up

Information about the battery backup feature for power failure protection.

Use of the Programming “Hot Key"

To Program a Hot Key From the Instrument (Upload)

Steps to save the current instrument configuration to a "Hot Key".

How to Program an Instrument Using a Hot Key (Download)

Steps to load a saved configuration from a "Hot Key" to the instrument.

Alarm Signals

Silencing Buzzer

How to mute the audible alarm buzzer when an alarm occurs.

Alarm Recovery

Explains how different alarm conditions are cleared or reset automatically.

Technical Data

Connections

Default Parameter Map

Parameter List

Related product manuals