7 Scripting 25
7.9 Configuration
The scripting server has the following configurable parameters:
Scriptingsettings
Scriptstepdelay
1
seconds.
Usermessageforcedisplay
timeout
0
seconds.
Usermessagetimeout seconds.
Startonrebootat
[Disabled]
Tracescript
Submit
User script configuration
Script step delay - the time in seconds to wait after executaion of a legacy API function (e.g. ON, OFF).
Modern API functions don't have internal delays; the delay() function should be used there.
User message timeout - the time in seconds after which user messages (displayed e.g. with the DISPLAY
command) disappear even if no keys are pressed on the LCD and no changes have been made to the relay
state (leave empty to have the messages displayed indefinitely).
User message force display timeout - the time in seconds during which user messages are displayed even
despite keys being pressed on the LCD or changes to the relay state (leave empty to have the messages
forcefully displayed indefinitely).
Start on reboot at - the scripting function to start at cold boot.
Trace script - enable diagnostic output about script progress to system log.